Brocade Fabric OS v7.1.2a Release Notes v1.0

Closed with Code Change in Prior released version of FOS
Defect ID:
DEFECT000477795
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.2.0
Technology Area:
Web Tools
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
Users will not be able to see the current data for SFP diagnostics.
Condition:
SFP tab on webtools not display the current data even after selecting “Refresh Now” option.
Workaround:
Use CLI sfpshow
Defect ID:
DEFECT000477854
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Traffic Management
Reported In Release:
FOS7.0.2
Technology Area:
ICLs - Inter-chassis Links
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
CRC with good EOF errors are reported on multiple ICL ports in DCX
Condition:
This issue is seen rarely on DCX platforms
Defect ID:
DEFECT000482106
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
FICON
Reported In Release:
FOS7.1.0
Technology Area:
FICON CUP
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
Fbusy encountered when trying to bring up CUP connections following FCIP tunnel bounces.
Condition:
This may be seen only on FICON switches when attempting to bring up CUP connection after an
FCIP tunnel is bounced.
Defect ID:
DEFECT000482736
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
FICON
Reported In Release:
FOS7.1.0
Technology Area:
FICON CUP
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
Enabling FMS mode leads to floods of internal FICU raslog after code upgrade.
Condition:
This happens when there are 10 or more outstanding FRU failure messages.
Defect ID:
DEFECT000484414
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Virtualization
Reported In Release:
FOS7.0.2
Technology Area:
Access Gateway
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
Under rare conditions, Access Gateway(AG) entries stay in management server (MS) database even
after removing them from the fabric.
FOS firmware is expected to remove these stale entries during execution of agshow CLI command.
However, due to a timing issue the stale entries may not be removed from the database when agshow
CLI command is run.
Condition:
This may be observed on a switch running firmware version higher than v7.0.
Fabric OS v7.1.2a Release Notes v1.0 Page 35 of 38