Brocade Fabric OS v7.1.2a Release Notes v1.0
Closed with Code Change in Prior released version of FOS
Defect ID:
DEFECT000462091
Technical Severity:
Medium
Probability:
Low
Product:
FOS
Technology:
Other
Reported In Release:
FOS7.1.0
Technology Area:
Other
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
ipfilter behavior varies depending on IPFC configuration
Condition:
This is a general issue, not on a specific switch, and can be reproduced by the following steps:
1. Set the ipfilter.
2. Try to login from another ip address that is not allowed via telnet, ssh, and http.
3. Hit errdump.
Defect ID:
DEFECT000462673
Technical Severity:
Low
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.0.0
Technology Area:
Fabric Watch
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
Some of the Fabric Watch keys are multiplied by 100 after configdownload.
Condition:
When configdownload a configuration file with "thresh.Pktloss" keys
Workaround:
Use fabric watch threshold management CLI rather than configdownload for "thresh.Pktloss" keys
Defect ID:
DEFECT000466131
Technical Severity:
Low
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.1.1
Technology Area:
Fabric Watch
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
FW-1440 about empty slot is generated at hafailover
Condition:
Fru state may be incorrectly updated in Logical Switch
Recovery:
No loss of functionality, message can be ignored.
Defect ID:
DEFECT000467843
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.0.2
Technology Area:
End-to-end Performance
Monitoring
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
The TX counter remains at "0x0000000100000000" after clears stats of EE performance monitors.
Condition:
No special condition is required: When EE monitor counters(TX/RX) are cleared on a port, 1 in top
value of EE monitor counters(Tx/Rx) are not cleared. There is no functional impact.
Defect ID:
DEFECT000470487
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.2.0
Technology Area:
Fabric Watch
Closed In Release(s):
FOS7.1.2a(Fixed)
Symptom:
Erroneous FW-1190 error messages seen on different VEX tunnels:
Event: , VEXport#3/16,Packet Loss, is above high boundary(High=100, Low=0). Current value is
1176 Percentage(%).
Severity: Warning
Condition:
When using Fabric Watch and SNMP, etc to monitor a switch, E-port pktloss raslog, VE-port and E-
port pktloss trap can be misleading.
Fabric OS v7.1.2a Release Notes v1.0 Page 33 of 38