Brocade Fabric OS v7.1.2a Release Notes v1.0
Supported Products and FOS Interoperability
Brocade DCX/DCX-4S with FA4-18 blade(s) DCX requires v6.0.x or later
6
, DCX-4S
requires 6.2.x or later
5 6
Brocade DCX 8510-8/DCX 8510-4
FOS v7.0 or later
Brocade 6510
FOS v7.0 or later
Brocade 6505
FOS v7.0.1 or later
Brocade 6520
FOS v7.1 or later
48000 with FA4-18 blade(s), Brocade 7600
V6.2.2 or later
6
Secure Fabric OS (on any model)
Not Supported
Mi10k, M6140, ED-6064, ES-3232, ES-4300, ES-4400, ES-4500, ES-
4700 (McDATA Fabric Mode and Open Fabric Mode)
1
Direct E_Port connections are not
supported – must use FCR running
pre-FOS v7.1.
M-EOS v9.9.5 or later
McDATA ED-5000 32-port FC director
Not Supported
Multi-Protocol Router Interoperability
Brocade 7420 Not supported
Brocade 7500 and FR4-18i blade V6.2.2 and higher
4 6 8
McDATA SANRouters 1620 and 2640
Not Supported
NOS (VDX Platform) Interoperability
Brocade VDX6710, VDX6720, VDX6730 NOS v2.1.1 or later
7
Brocade VDX8770 NOS 3.0 or later
Table Notes:
1
When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in
order to configure the frame redirection zone information in the edge fabric.
2
When directly attached to a Host or Target that is part of an encryption flow.
3
These platforms may not be directly attached to hosts or targets for encryption flows.
4
McDATA 1620 and 2640 SANRouters should not be used with FOS-based routing (FCR) for connections to the same
edge fabric.
5
FA4-18 is not supported in a DCX/DCX-4S that is running FOS v7.0 or later
6
If operating with
FOS v6.2.2e or earlier
, Adaptive Networking QoS must be disabled when connecting to 16G FC
platform. Otherwise, ISL will segment.
7
Connectivity to FC SAN is established via VDX6730 connected to FCR running FOS v7.0.1 or later. FCR platforms
supported include 5100, VA-40FC, 5300, 7800, DCX, DCX-4S, DCX 8510-8, DCX 8510-4, 6510, 6520 (requires FOS
v7.1 or later). For higher FCR backbone scalability (refer to separate “Brocade SAN Scalability Guidelines”
documentation for details), please use 5300, 6520, DCX, DCX-4S, DCX 8510-8, DCX 8510-4.
8
FR4-18i and FC10-6 are not supported on DCX/DCX-4S on FOS v7.1 or later.
Fabric OS v7.1.2a Release Notes v1.0 Page 15 of 38