Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 53 of 53
SNMP Trap: cpqNic3RedundancyReduced – 18014 in CPQNIC.MIB
Symptom: This trap will be sent any time a physical adapter in a logical adapter group changes to the
Failed condition, but at least one physical adapter remains in the OK condition. This can be caused by
loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or
Switch failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the
adapter, Hub, or Switch may need replacement.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
cpqNicIfLogMapAdapterOKCount
Supporting SNMP trap description: "Redundancy decreased by adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort]."