Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 51 of 53
switch failures can also cause this condition.
User action: Check the cables to the adapter and the hub or switch. If no cable problems are found, the
adapter, hub, or switch might need replacement.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapAdapterOKCount
Supporting SNMP trap description: “Redundancy decreased by adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort].”
18009 - cmanicd
Log message: “Virus-like activity detected”
SNMP trap: cpqNicVirusLikeActivityDetected – 1 8009 in CPQNIC.MIB
Symptom: This trap is sent when the Virus Throttle Filter Driver detects virus like activity.
User action: The system reporting this trap requires immediate attention.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSiServerSystemId
Supporting SNMP trap description: “Virus-like activity detected”
18010 - cmanicd
Log message: “Virus-like activity no longer detected”
SNMP trap: cpqNicVirusLikeActivityStopped – 18010 in CPQNIC.MIB
Symptom: This trap is sent when the Virus Throttle Filter Driver no longer detects virus like activity.
User action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSiServerSystemId
Supporting SNMP trap description: “Virus-like activity no longer detected”
18011 – cmanicd
Log message: "Connectivity is restored for adapter in slot %d, port %d."
SNMP Trap: cpqNic3ConnectivityRestored – 18011 in CPQNIC.MIB
Symptom: This trap will be sent any time connectivity is restored to a logical adapter. This occurs when
the physical adapter in a single adapter configuration returns to the OK condition or at least one physical
adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a
faulty cable or re-attaching a cable that was unplugged.
User Action: None required
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName