Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 33 of 53
Symptom: The DC-DC Power Converter condition has been set to Degraded for the specified chassis,
slot, and socket.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
cpqHePwrConvSlot
cpqHePwrConvSocket
Supporting SNMP trap description: “The Power Converter Degraded on Chassis
[cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”
6044 - cmahealthd
Log message: “The DC-DC Power Converter condition has been set to Failed.”
SNMP trap: cpqHe3PowerConverterFailed - 6044 in CPQHLTH.MIB
Symptom: The DC-DC Power Converter condition has been set to Failed for the specified chassis, slot,
and socket.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
cpqHePwrConvSlot
cpqHePwrConvSocket
Supporting SNMP trap description: “The Power Converter Failed on Chassis [cpqHePwrConvChassis],
Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”
6045 - cmahealthd
Log message: “The DC-DC Power Converters have lost redundancy.”
SNMP trap: cpqHe3PowerConverterRedundancyLost - 6045 in CPQHLTH.MIB
Symptom: The DC-DC Power Converters have lost redundancy for the specified chassis.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
Supporting SNMP trap description: “The Power Converters are no longer redundant on Chassis
[cpqHePwrConvChassis] .”
6046 - cmahealthd
Log message: “Cache accelerator parity error occurred. A cache module needs to be replaced.”
SNMP trap: cpqHe3CacheAccelParityError - 6046 in CPQHLTH.MIB
Symptom: A cache accelerator parity error indicates a cache module needs to be replaced. The error
information is reported in the variable cpqHeEventLogErrorDesc.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “Cache Accelerator errors may require a replacement module.” 6047 –
6047 - cmahealthd
Log message: “Online Spare Memory Engaged”
SNMP trap: cpqHeResilientMemOnlineSpareEngaged - 6047 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection
subsystem has detected a memory fault. The Online Spare Memory has been activated.
User action: Schedule server down time to replace the faulty memory.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags