Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 30 of 53
Symptom: One or more power on self-test (POST) errors occurred. POST errors occur during the server
restart process.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “Errors occurred during server restart.”
6028 - cmahealthd
Log message: “The server power supply status has become degraded.”
SNMP trap: cpqHe3FltTolPwrSupplyDegraded - 6028 in CPQHLTH.MIB
Symptom: The fault tolerant power supply sub-system condition has been set to Degraded.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “The server power supply status has become degraded.”
6029 – cmahealthd
Log message: “A correctable memory log entry indicates a memory module needs to be replaced.”
SNMP trap: cpqHe3CorrMemReplaceMemModule - 6029 in CPQHLTH.MIB
Symptom: A correctable memory log entry indicates a memory module needs to be replaced. The errors
have been corrected, but the memory module should be replaced. The error information is reported in the
variable cpqHeCorrMemErrDesc.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
Supporting SNMP trap description: “Correctable memory errors require a replacement memory module.”
6032 - cmahealthd
Log message: “The power supply has lost redundancy.”
SNMP trap: cpqHe3FltTolPowerRedundancyLost - 6032 in CPQHLTH.MIB
Symptom: The fault tolerant power supplies have lost redundancy for the specified chassis.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeFltTol PowerSu pplyChassis
Supporting SNMP trap description: “The Power Supplies are no longer redundant on Chassis
[cpqHeFltTolPowerSupplyChassis].”
6033 - cmahealthd
Log message: “The power supply was inserted.”
SNMP trap: cpqHe3FltTolPowerSupplyInserted - 6033 in CPQHLTH.MIB
Symptom: A fault tolerant power supply has been inserted in the specified chassis and bay location.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqHeFltTol PowerSu pplyChassis
cpqHeFltTolPowerSupplyBay
Supporting SNMP trap description: “The Power Supply Inserted on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].”
6034 - cmahealthd
Log message: “The power supply was removed.”
SNMP trap: cpqHe3FltTolPowerSupplyRemoved - 6034 in CPQHLTH.MIB
Symptom: A fault tolerant power supply has been removed from the specified chassis and bay location.
Supporting SNMP trap data: