Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 24 of 53
Log message: “Accelerator Board Battery Failed. Chassis name: [cpqSsChassisName], I/O slot:
[cpqFcaAccelBoxIoSlot].”
SNMP trap: cpqFca2AccelBatteryFailed - 1 601 9 in CPQFCA.MIB
Symptom: External Array Accelerator Board Battery Failed. The agent has detected a battery failure
associated with the Array Accelerator Cache Board.
User action: Replace the Accelerator Cache Board.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP trap description: “Battery status is failed.”
16020 - cmafcad
Log message: “Array Controller status change. Chassis name: [cpqSsChassisName], I/O slot:
[cpqFcaCntlrBoxIoSlot]. Status is now [cpqFcaCntlrStatus string].”
SNMP trap: cpqFca2CntlrStatusChange - 1 6020 in CPQFCA.MIB
Symptom: External Array Controller Status Change. The agent has detected a change in the status of an
External Array Controller. The variable cpqFcaCntlrStatus indicates the current controller status.
User action: If the controller status is offline(4), access to the storage box has been lost. Check the
storage box and all Fibre Channel connections for problems.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaCntlrBoxIoSlot
cpqFcaCntlrStatus
cpqFcaCntlrModel
cpqFcaCntlrSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP trap description: “Status is now [cpqFcaCntlrStatus].”
16022 - cmafcad
Log message: “Logical drive status change. Chassis name: [cpqSsChassisName], Storage box:
[cpqFcaLogDrvBoxI ndex] . Status is now [cpqFcaLog DrvStatus string] for logical drive
[cpqFcaLogDrvIndex].”
SNMP trap: cpqExtArrayLogDrvStatusChange - 16022 in cpqfca.mib
Symptom: External Array Logical Drive Status Change. The agent has detected a change in the status of
an External Array logical drive. The variable cpqFcaLogDrvStatus indicates the current logical drive
status.
User action: If the logical drive status is failed, examine the array for failed drives that need replacement.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaLogDrvBoxIndex
cpqFcaLogDrvIndex
cpqFcaLogDrvStatus