Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30

Page 19 of 53
cpqSsBackplaneVendor
cpqSsBackplaneModel
cpqSsBackplaneSerialNumber
cpqSsBackplaneTempStatus
Supporting SNMP trap description: “Storage system temperature status changed to
[cpqSsBackplaneTempStatus].”
8024 - cmafcad
Log message: “Backplane Power Status Change. Chassis Name: [cpqSsChassisName], Status:
[cpqSsBackplaneFtpsStatus string].”
SNMP trap: cpqSsExBackplanePowerSupplyStatusChange - 8024 in CPQSTSYS.MIB
Symptom: Storage system power supply status change. The agent has detected a change in the power
supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status.
User action: If the power supply status is degraded, take action to restore power or replace the failed
power supply.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsBackplaneIndex
cpqSsBackplaneVendor
cpqSsBackplaneModel
cpqSsBackplaneSerialNumber
cpqSsBackplaneFtpsStatus
Supporting SNMP trap description: “Storage system power supply status changed to
[cpqSsBackplaneFtpsStatus].”
8025 - cmafcad
Log message: “Redundant Server Option Status Change. Storage system redundant server option status
changed to [cpqSsChassisRsoStatus string].“
SNMP trap: cpqSsExRecoveryServerStatusChange - 8025 in CPQSTSYS.MIB
Symptom: Storage system recovery server option status change. The agent has detected a change in the
recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the
current status.
User action: If the RSO status is noSecondary(6) or linkDown(7), ensure the secondary server is
operational and all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or
secondaryRunningUser(9), examine the primary server for failed components.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsChassisRsoStatus
cpqSsChassisIndex
Supporting SNMP trap description: “Storage system recovery server option status changed to
[cpqSsChassisRsoStatus].”
8029 - cmasasd
Log message: " Storage box fan status changed: Status changed from [Old cpqSsBoxFanStatus] to [new
cpqSsBoxFanStatus]."
SNMP trap: cpqSs6FanStatusChange – 8029 in cpqstsys.mib
Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a
storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
User action: If the fan status is degraded or failed, replace any failed fans.