Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.30
Page 16 of 53
8011 - cmascsid
Log message: “Storage system temperature OK.”
SNMP trap: cpqSs3TempOk - 8011 in CPQSTSYS.MIB
Symptom: Storage system temperature ok. The temperature status has been set to OK. The storage
system's temperature has returned to normal operating range. It can be reactivated by the administrator.
User action: None
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsBoxTempStatus
Supporting SNMP trap description: “Storage System temperature ok.”
8012 - cmascsid
Log message: “Storage system side panel is re-installed on unit.”
SNMP trap: cpqSs3SidePanelInPlace - 8012 in CPQSTSYS.MIB
Symptom: Storage System side panel is in place. The side panel status has been set to in place. The
storage system's side panel has returned to a properly installed state.
User action: None.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsBoxSidePanelStatus
Supporting SNMP trap description: “Side panel is re-installed on unit.”
8013 - cmascsid
Log message: “Storage system side panel is removed from unit.”
SNMP trap: cpqSs3SidePanelRemoved - 8013 in CPQSTSYS.MIB
Symptom: Storage system side panel is removed. The side panel status has been set to removed. The
storage system's side panel is not in a properly installed state. This situation might result in improper
cooling of the drives in the storage system because of airflow changes caused by the missing side panel.
User action: Replace the storage system side panel.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsBoxSidePanelStatus
Supporting SNMP trap description: “Side panel is removed from unit.”
8015 - cmascsid
Log message: “A storage system power supply unit has become degraded.”
SNMP trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB
Symptom: A storage system power supply status has been set to degraded.
User action: Take action to restore power or replace any failed storage system power supply.
Supporting SNMP trap data:
sysName
cpqHoTrapFlags
cpqSsBoxFltTolPwrSupplyStatus
Supporting SNMP trap description: “A storage system power supply unit has become degraded”
8018 - cmafcad
Log message: “Power Supply UPS Status Change. Chassis Name: [cpqSsChassisName], UPS Status:
[cpqSsPowerSupplyUpsStatus string].”
SNMP trap: cpqSsExPowerSupplyUpsStatusChange - 8018 in CPQSTSYS.MIB
Symptom: Storage system power supply UPS status change. The agent has detected a change status of
a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates
the current status.