Linux Trap ID and SNMP Traps Reference Guide For use with SmartStart version 8.
Legal notices © Copyright 2006−2009 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents Contents.........................................................................................................................................................................3 Introduction ...................................................................................................................................................................4 Where to go for additional help ..................................................................................................................
Introduction This guide contains a listing of the Linux Trap ID messages associated with SNMP traps that are generated by the HP Insight Management Agents for Servers for Linux. Each event entry has the corresponding SNMP trap number used by the agents. Where to go for additional help In addition to this guide, the following information sources are available: User documentation HP Insight Manager software Telephone numbers If you have purchased a Care Pack (service upgrade), call 1-800-633-3600.
Foundation agents Trap IDs: 10003-10008 10003 - cmathreshd Log message: “Compaq Generic Test Trap (10003): %s” SNMP trap: cpqHo2GenericTrap - 1003 in PQHOST.MIB Symptom: Generic trap. Supporting SNMP trap data: sysName cpqHoTrapFlags cpqHoGenericData Supporting SNMP trap description: “[cpqHoGenericData]” 10004 - cmathreshd Log message: “%s: Variable %s has value %d <= %d.” SNMP trap: cpqMe2FallingAlarm - 10004 in CPQTHRESH.MIB Symptom: Falling Threshold passed.
cpqMeAlarmSeverity cpqMeAlarmExtendedDescription Supporting SNMP trap description: “[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAla rmValue] >= [cpqMeAlarmRisingThreshold].” 10006 - cmathreshd Log message: “Falling Threshold Trap” “Alarm Variable %s” “Threshold Value %d” “Alarm Value %d” “Alarm Sample Type %s” “Alarm Owner %s” “Alarm Severity %d” “Alarm Description %s” SNMP trap: cpqMeFallingAlarmExtended - 10006 in CPQTHRSH.MIB Symptom: Falling Threshold passed.
Supporting SNMP trap data: sysName cpqHoTrapFlags cpqMeAlarmVariable cpqMeAlarmSampleType cpqMeAlarmValue cpqMeAlarmFallingThreshold cpqMeAlarmOwner cpqMeAlarmSeverity cpqMeAlarmExtendedDescription Supporting SNMP trap description: “[cpqMeAlarmOwner]: Variable [cpqMeAlarmVariable] has value [cpqMeAla rmValue] >= [cpqMeAlarmRisingThreshold].” Storage agents Trap IDs: 3016-3047 3016 – cmaidad Log message: “Controller Role Changes: Controller in slot [cpqDaCntlrSlot] is now active.
Supporting SNMP trap description: “Status is now [cpqDaCntl rBoardStatus].” 3034 - cmaidad Log message: “Logical Drive Status Change: [cpqDaCntl rHwLocation], Drive: [cpqDaLogDrvI ndex]. Status is now [cpqDaLogDrvStatus].” SNMP trap: cpqDa6LogDrvStatusChange - 3034 in CPQIDA.MIB Symptom: Logical Drive Status Change. The agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status.
3040 - cmaidad Log message: “Accelerator Board Battery status change, slot number: [cpqDaCntlrSlot]. Battery failed. Status: %s.” SNMP trap: cpqDa6AccelBatteryFailed - 3040 in CPQIDA.MIB Symptom: Accelerator Board Battery Failed. The agent has detected a battery failure associated with the array accelerator cache board. User action: Replace the Accelerator Cache Board.
User action: If the tape library door is open, close the tape library door.
cpqDaTapeDrvLunIndex cpqDaTapeDrvName cpqDaTapeDrvFwRev cpqDaTapeDrvSerialNumber Supporting SNMP trap description: “Cleaning is needed for the tape drive.” 3045 - cmaidad Log message: “Tape Drive Cleaning Tape Needs Replacing, slot number: [cpqDaCntlrSlot], bus number: [cpqDaTapeDrvBusIndex], drive ID: [cpqDaTapeDrvScsiIdIndex]” SNMP trap: cpqDa6TapeDriveCleanTapeReplace - 3045 in CPQIDA.MIB Symptom: Tape Drive Cleaning Tape Needs Replacing.
User action: If the spare drive status is failed, replace the drive. Supporting SNMP trap data: sysName cpqHoTrapFlags cpqDaCntlrHwLocation cpqDaSpareCntlrIndex cpqDaSparePhyDrvIndex cpqDaSpareStatus cpqDaSpareLocationString cpqDaSpareBusNumber Supporting SNMP trap description: “Spare Status is now [cpqDaSpareStatus].” Trap IDs: 5008-5025 5008 - cmascsid Log message: “Tape drive cleaning required: Status is now [cpqTapePhyDrvCondition].
cpqTapeLibrarySerialNumber Supporting SNMP trap description: “Tape library [cpqTapeLibrarySerialNumber] door closed” 5018 - cmascsid Log message: “Tape Library Status Changed: Status is now [cpqTapeLibraryState].” SNMP trap: cpqTapeLibraryStatusChange - 5018 in CPQSCSI.MIB Symptom: Tape Library Status Change. The agent has detected a change in the status of a tape library. The current tape library status is indicated in the cpqTapeLibraryState variable.
cpqScsiPhyDrvVendor cpqScsiPhyDrvModel cpqScsiPhyDrvFWRev cpqScsiPhyDrvSerialNum cpqScsiPhyDrvOsName Supporting SNMP trap description: “Status is now [cpqScsiPhyDrvStatus].” 5022 - cmasasd Log message: “SAS Physical Drive Status Changed: Status changed from [previous cpqSasPhyDrvStatus] to [current cpqSasPhyDrvStatus].” SNMP trap: cpqSasPhyDrvStatusChange - 5022 in CPQSCSI.MIB Symptom: Physical Drive Status Change. The agent has detected a change in the status of a SAS or SATA physical drive.
sysName cpqHoTrapFlags cpqSasHbaHwLocation cpqSasTapeDrvLocationString cpqSasTapeDrvHbaIndex cpqSasTapeDrvIndex cpqSasTapeDrvName cpqSasTapeDrvFWRev cpqSasTapeDrvSerialNumber cpqSasTapeDrvSasAddress cpqSasTapeDrvStatus Supporting SNMP trap description: “Status is now [cpqSasPhyDrvStatus].” Trap IDs: 8008-8031 8008 - cmascsid Log message: “Storage system fan status changed to [cpqSsBoxFanStatus string].” SNMP trap: cpqSs3FanStatusChange - 8008 in CPQSTSYS.
8011 - cmascsid Log message: “Storage system temperature OK.” SNMP trap: cpqSs3TempOk - 8011 in CPQSTSYS.MIB Symptom: Storage system temperature ok. The temperature status has been set to OK. The storage system's temperature has returned to normal operating range. It can be reactivated by the administrator. User action: None Supporting SNMP trap data: sysName cpqHoTrapFlags cpqSsBoxTempStatus Supporting SNMP trap description: “Storage System temperature ok.
User action: If the UPS status is powerFailed(4) or batteryLow(5), take action to restore power to the UPS. Supporting SNMP trap data: sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqSsPowerSupplyBay cpqSsPowerSupplyUpsStatus Supporting SNMP trap description: “Storage system power supply UPS status changed to [cpqSsPowerSupplyUpsStatus].” 8019 - cmafcad Log message: “Temperature Sensor Status Change.
Log message: “Power Supply Status Change. Chassis Name: [cpqSsChassisName], Power Supply Status: [cpqSsPowerSu pplyStatus string].” SNMP trap: cpqSsEx2PowerSupplyStatusChange - 8021 in CPQSTSYS.MIB Symptom: Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User action: If the power supply status is failed, take action to restore power or replace the failed power supply.
cpqSsBackplaneVendor cpqSsBackplaneModel cpqSsBackplaneSerialNumber cpqSsBackplaneTempStatus Supporting SNMP trap description: “Storage system temperature status changed to [cpqSsBackplaneTempStatus].” 8024 - cmafcad Log message: “Backplane Power Status Change. Chassis Name: [cpqSsChassisName], Status: [cpqSsBackplaneFtpsStatus string].” SNMP trap: cpqSsExBackplanePowerSupplyStatusChange - 8024 in CPQSTSYS.MIB Symptom: Storage system power supply status change.
Supporting SNMP trap data: sysName cpqHoTrapFlags cpqSsBoxCntlrHwLocation cpqSsBoxCntlrIndex cpqSsBoxBusIndex cpqSsBoxVendor cpqSsBoxModel cpqSsBoxSerialNumber cpqSsBoxFanStatus cpqSsBoxLocationString Supporting SNMP trap description: " Storage box fan status changed: Status changed from [Old cpqSsBoxFanStatus] to [new cpqSsBoxFanStatus].
cpqSsBoxModel cpqSsBoxSerialNumber cpqSsBoxFltTolPwrSupplyStatus cpqSsBoxLocationString Supporting SNMP trap description: “Storage box power supply status changed: Status changed from [old cpqSsBoxFltTolPwrSupplyStatus] to [new cpqSsBoxFltTolPwrSupplyStatus]” Trap IDs: 14004-16028 14004 - cmaided Log message: “ATA Disk Status Changes” SNMP trap: cpqIdeAtaDiskStatusChange - 14004 in CPQIDE.MIB Symptom: ATA Disk Status Change. The agent has detected a change in the status of an ATA disk drive.
sysName cpqHoTrapFlags cpqSsChassisName cpqSsChassisTime cpqFcaSpareBusNumber cpqFcaSpareBay cpqFcaSpareStatus Supporting SNMP trap description: “Spare Status is now [cpqFcaSpareStatus] on bus [cpqFcaSpareBusNumber].” 16008 - cmafcad Log message: "Status is now %d for tape controller %s." SNMP trap: cpqFcTapeCntlrStatusChange - 16008 in cpqfca.mib Symptom: This trap signifies that the agent has detected a change in the status of a Fiber Channel Tape Controller.
cpqSsChassisName cpqSsChassisTime cpqFcaPhyDrvBusNumber cpqFcaPhyDrvBay cpqFcaPhyDrvStatus cpqFcaPhyDrvModel cpqFcaPhyDrvSerialNum cpqFcaPhyDrvFWRev cpqFcaPhyDrvFailureCode Supporting SNMP trap description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on bus [cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].” 16017 - cmafcad Log message: “Accelerator Board status change. Chassis name: [cpqSsChassisName], I/O slot: [cpqFcaAccelBoxIoSlot]. Status is now [cpqFcaAccelStatus string].
Log message: “Accelerator Board Battery Failed. Chassis name: [cpqSsChassisName], I/O slot: [cpqFcaAccelBoxIoSlot].” SNMP trap: cpqFca2AccelBatteryFailed - 1 601 9 in CPQFCA.MIB Symptom: External Array Accelerator Board Battery Failed. The agent has detected a battery failure associated with the Array Accelerator Cache Board. User action: Replace the Accelerator Cache Board.
cpqFcaLogDrvOsName cpqFcaLogDrvFaultTol cpqFcaLogDrvSize Supporting SNMP trap description: “Status is now [cpqFcaLogDrvStatus].” 16023 - cmafcad Log message: “Tape Drive Status Change: Status is now [cpqFcTapeDriveStatus] for [cpqFcTapeDriveModel] on port [cpqFcTapeDriveScsi Bus] target [cpqFcTapeDriveScsiTarget].” SNMP trap: cpqExtTapeDriveStatusChange - 16023 in cpqfca.mib Symptom: External Tape Drive Status Change. The agent has detected a change in the status of an External Tape Drive.
Supporting SNMP trap data: sysName cpqHoTrapFlags cpqFcTapeDriveCntlrIndex cpqFcTapeDriveScsiBus cpqFcTapeDriveScsiTarget cpqFcTapeDriveScsiLun cpqFcTapeDriveModel cpqFcTapeDriveFWRev cpqFcTapeDriveSerialNumber cpqFcTapeDriveLocation Supporting SNMP trap description: “Cleaning tape needs replacing” 16026 - cmafcad Log message: "Status is now %d for the tape library." SNMP trap: cpqExtTapeLibraryStatusChange - 16026 in cpqfca.mib Symptom: External Tape Library Status Change.
16028 - cmafcad Log message: “Host controller status change: slot [cpqFcaHostCntlrSlot], status is now [current cpqFcaHostCntlrStatus]” SNMP trap: cpqFca3HostCntlrStatusChange- 16028 in cpqfca.mib Symptom: Fibre Channel Host Controller Status Change. The agent has detected a change in the status of a Fibre Channel Host Controller. The variable cpqFcaHostCntlrStatus indicates the current controller status. User action: If the controller status is failed, replace the controller.
Supporting SNMP trap description: “Too many memory errors - tracking now disabled.” 6017 - cmahealthd Log message: “The system will be shutdown due to a thermal condition.” SNMP trap: cpqHe3ThermalTempFailed - 601 7 in CPQHLTH.MIB Symptom: The temperature status has been set to Failed. The system will be shut down because of this thermal condition. Supporting SNMP trap data: sysName cpqHoTrapFlags Supporting SNMP trap description: “System will be shut down due to this thermal condition.
6022 - cmahealthd Log message: “A non-operational system fan has returned to normal operation.” SNMP trap: cpqHe3ThermalSystemFanOk – 6022 - CPQHLTH.MIB Log message: "System fan has returned to normal operation." Supporting SNMP trap data: sysName cpqHoTrapFlags Supporting SNMP trap description: “System fan has returned to normal operation.” 6023 - cmahealthd Log message: “A processor fan is not operating normally. The system will be shutdown.” SNMP trap: cpqHe3ThermalCpuFanFailed - 6023 in CPQHLTH.
Symptom: One or more power on self-test (POST) errors occurred. POST errors occur during the server restart process. Supporting SNMP trap data: sysName cpqHoTrapFlags Supporting SNMP trap description: “Errors occurred during server restart.” 6028 - cmahealthd Log message: “The server power supply status has become degraded.” SNMP trap: cpqHe3FltTolPwrSupplyDegraded - 6028 in CPQHLTH.MIB Symptom: The fault tolerant power supply sub-system condition has been set to Degraded.
sysName cpqHoTrapFlags cpqHeFltTol PowerSu pplyChassis cpqHeFltTolPowerSupplyBay Supporting SNMP trap description: “The Power Supply Removed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].” 6035 - cmahealthd Log message: “The redundant fan has degraded.” SNMP trap: cpqHe3FltTolFanDegraded - 6035 in CPQHLTH.MIB Symptom: The fault tolerant fan condition has been set to Degraded for the specified chassis and fan.
Log message: “The redundant fan was removed.” SNMP trap: cpqHe3FltTolFanRemoved - 6039 in CPQHLTH.MIB Symptom: A fault tolerant fan has been removed from the specified chassis and fan location. Supporting SNMP trap data: sysName cpqHoTrapFlags cpqHeFltTolFanChassis cpqHeFltTolFanIndex Supporting SNMP trap description: “The Fan Removed on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex].” 6040 - cmahealthd Log message: “The temperature status has failed.
Symptom: The DC-DC Power Converter condition has been set to Degraded for the specified chassis, slot, and socket. Supporting SNMP trap data: sysName cpqHoTrapFlags cpqHePwrConvChassis cpqHePwrConvSlot cpqHePwrConvSocket Supporting SNMP trap description: “The Power Converter Degraded on Chassis [cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].” 6044 - cmahealthd Log message: “The DC-DC Power Converter condition has been set to Failed.
Supporting SNMP trap description: “The Advanced Memory Protection subsystem has engaged the online spare memory.” 6048 - cmahealthd Log message: “The power supply is OK.” SNMP trap: cpqHe4FltTolPowerSupplyOk - 6048 in CPQHLTH.MIB Symptom: The fault tolerant power supply condition has been set back to the OK state for the specified chassis and bay location.
Supporting SNMP trap data: sysName cpqHoTrapFlags cpqHeFltTol PowerSu pplyChassis cpqHeFltTolPowerSupplyBay cpqHeFltTolPowerSupplyStatus cpqHeFltTolPowerSupplyModel cpqHeFltTolPowerSupplySerialNumber cpqHeFltTolPowerSupplyAutoRev cpqHeFltTolPowerSupplyFirmwareRev cpqHeFltTolPowerSupplySparePartNum cpqSiServerSystemId Supporting SNMP trap description: “The Power Supply is Failed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplySt
SNMP trap: cpqHe3FltTolPowerRedundancyRestore - 6054 in CPQHLTH.MIB Symptom: The fault tolerant power supplies have returned to a redundant state for the specified chassis. User action: None required Supporting SNMP trap data: sysName cpqHoTrapFlags cpqHeFltTol PowerSu pplyChassis Supporting SNMP trap description: “The Power Supplies are now redundant on Chassis [cpqHeFltTolPowerSupplyChassis].” 6055 - cmahealthd Log message: "The Fans are now redundant on Chassis %d.
sysName cpqHoTrapFlags cpqHeResMem2BoardNum cpqHeResMem2CpuNum cpqHeResMem2RiserNum cpqHeResMem2ModuleNum cpqHeResMem2ModulePartNo cpqHeResMem2ModuleSize cpqSiServerSystemId Supporting SNMP trap description: “Correctable memory errors require a replacement of the memory module in slot [cpqHeResMem2BoardNum], cpu [cpqHeResMem2CpuNum], riser [cpqHeResMem2RiserNum], socket [cpqHeResMem2ModuleNum].
Supporting SNMP trap data: sysName cpqHoTrapFlags cpqHeResMem2BoardSlotNum cpqHeResMem2BoardCpuNum cpqHeResMem2BoardRiserNum Supporting SNMP trap description: “Memory Board or Cartridge Bus Error Detected in Slot[cpqHeResMem2BoardSlotNum] , Cpu[cpqHeResMem2BoardCpuNum], Riser[cpqHeResMem2BoardRiserNum]." 6068 - cmahealthd Log message: "The Advanced Memory Protection subsystem has engaged the LockStep memory." SNMP trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.
9004 - cmasm2d Log message: “The Remote Insight Battery has failed and needs to be replaced” SNMP trap: cpqSm2BatteryFailed - 9004 in CPQSM2.MIB Symptom: Remote Insight Battery Failed. The Remote Insight battery has failed and needs to be replaced. Supporting SNMP trap data: sysName cpqHoTrapFlags Supporting SNMP trap description: “Remote Insight battery failed.
Symptom: Mouse Cable Disconnected. The Remote Insight mouse cable was disconnected. Supporting SNMP trap data: sysName cpqHoTrapFlags Supporting SNMP trap description: “Remote Insight mouse cable disconnected.” 9010 - cmasm2d Log message: “The Remote Insight external power cable has been disconnected” SNMP trap: cpqSm2ExternalPowerCableDisconnected - 9010 in CPQSM2.MIB Symptom: External Power Cable Disconnected. The Remote Insight external power cable was disconnected.
22003 - cmarackd Log message: “Enclosure removed” SNMP trap: cpqRackEnclosureRemoved - 22003 in CPQRACK.MIB Symptom: The enclosure has been removed. An enclosure has been removed from the rack.
Supporting SNMP trap description: “The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to Failed.” 22016 - cmahealthd Log message: “Rack power supply removed” SNMP trap: cpqRackPowerSupplyRemoved - 2201 6 in CPQRACK.MIB Symptom: The power supply has been removed.
cpqRackPowerEnclosureName cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosu reTrapSequenceNu m Supporting SNMP trap description: “The power subsystem in enclosure [cpqRackPowerEnclosu reName] in rack [cpqRackName] is no longer redundant.” 22019 - cmahealthd Log message: “Rack power supply detected an input voltage problem.” SNMP trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB Symptom: The rack power supply detected an input line voltage problem.
cpqHoTrapFlags cpqRackName cpqRackUid cpqRackServerBladeEnclosu reName cpqRackServerBladePosition cpqRackServerBladeSparePartNumber cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosu reTrapSequenceNum Supporting SNMP trap description: “Server power on prevented to preserve redundancy in blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].” 22023 - cmahealthd Log message: “Server power on prevented inadequate power to power on.
User action: Check power enclosure connections or add power supplies. Supporting SNMP trap data: sysName cpqHoTrapFlags cpqRackName cpqRackUid cpqRackServerBladeEnclosu reName cpqRackServerBladePosition cpqRackServerBladeSparePartNumber cpqRackCommonEnclosureSerialNum cpqRackCommonEnclosu reTrapSequenceNu m Supporting SNMP trap description: “Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].
Symptom: Server blade removed. The server blade has been removed from the enclosure.
[cpqRackCommonEnclosureName], in rack [cpqRackName].” 22031 - cmahealthd Log message: “Power subsystem DC power problem.” SNMP trap: cpqRackPowerChassisDcPowerProblem - 22031 in CPQRACK.MIB Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.
Log message: “Power subsystem load balancing wire missing” SNMP trap: cpqRackPowerChassisLoadBalancingWireMissing - 22034 in CPQRACK.MIB Symptom: Power subsystem load balancing wire missing. The power subsystem load balancing wire is missing. User action: Connect the load balancing wire.
NIC agents Trap IDs: 18001-18014 18001 - cmanicd Log message: “Connectivity is restored for adapter in slot %d, port %d” SNMP trap: cpqNicConnectivityRestored - 1 8001 in CPQNIC.MIB Symptom: This trap is sent any time connectivity is restored to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition.
cpqNicIfPhysAdapterPartNumber ipAdEntAddr Supporting SNMP trap description: “Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort].” 18006 - cmanicd Log message: “Connectivity lost for adapter in slot %d, port %d.” SNMP trap: cpqNic2ConnectivityLost – 1 8006 in CPQNIC.MIB Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition.
switch failures can also cause this condition. User action: Check the cables to the adapter and the hub or switch. If no cable problems are found, the adapter, hub, or switch might need replacement.
cpqNicIfPhysAdapterPartNumber ipAdEntAddr cpqNicIfLogMapIPV6Address Supporting SNMP trap description: "Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort]." 18012 – cmanicd Log message: "Connectivity Lost for adapter in slot %d, port %d." SNMP Trap: cpqNic3ConnectivityLost – 18012 in CPQNIC.MIB Symptom: This trap will be sent any time the status of a logical adapter changes to the Failed condition.
SNMP Trap: cpqNic3RedundancyReduced – 18014 in CPQNIC.MIB Symptom: This trap will be sent any time a physical adapter in a logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch.