HP StorageWorks SmartStart EVA Storage 3.3 Release Notes (T5505-96052, August 2010)
Reason: The storage volume you created has not been detected. (7007,
blm_storage_volume_not_found)
This error occurs when the host on which you attempted to create the storage volume cannot connect
to the array through the fabric. Other management operations succeed because they use connections
to HP Command View EVA over Ethernet.
To resolve this situation, verify the zone configuration of the switch.
javaw.exe – Unable to locate component error
During HP Command View EVA installation, the following error message can appear:
javaw.exe - Unable To Locate Component; This application has failed to
start because WINSPOOL.DRV was not found. Re-installing the application
may fix this problem.
This error occurs when the HP Command View EVA installer attempts to create desktop icons for the
applications that it installed.
Because the error occurs after HP Command View EVA installed all applications, you do not need to
reinstall the applications. To continue, click OK.
If the desktop shortcuts do not appear, you can create them manually. Common executable files and
shortcuts are located as follows:
C:\Program Files\Hewlett-Packard\Sanworks\
Element Manager for StorageWorks HSV\
sssu.exe
HP StorageWorks Storage System Scripting Utility
https://localhost:2372
HP StorageWorks Command View EVA
C:\Program Files\Hewlett-Packard\EVA Per-
formance Monitor\evaperf.exe
HP StorageWorks Command View EVAPerf
Related documentation
PDF versions of relevant documentation for both HP SmartStart EVA Storage for Windows and HP
SmartStart EVA Storage for Linux are located on the HP StorageWorks SmartStart EVA CD for Windows
in the documentation folder.
You can also access all the documentation referenced in this document from the Manuals page of the
HP Business Support Center website http://www.hp.com/support/manuals. In the Storage section,
click Storage Software, and then select your product. For array-specific documents, click Disk Storage
Systems, and then select your array model.
Starting HP SmartStart EVA Storage for Linux
To start HP SmartStart EVA Storage for Linux:
1. Insert the HP SmartStart EVA Storage CD for Linux in the CD drive of the server you want to
configure.
2. Create a mount folder for the disk.
For example, mkdir /mnt/cdrom.
HP StorageWorks SmartStart EVA Storage 3.3 Release Notes 7