Using HP Smart Update Manager with HP Integrity Servers: Capabilities, Best Practices, and Troubleshooting

A pending SFW state may be activated by powering down the server. This does not mean removing A/C
power, but instead, it means removing main DC power to the main server, while the standby power to iLO
remains on. This can be done in several ways:
From iLO CLI command menu pc –off
From iLO GUI, power management
tab
From HP-UX
shutdown –h
Note: ‘shutdown r’ and ‘reboot’ do NOT
power down the server. These commands
might only result in HP-UX stopping, but the
firmware will not be activated. The systems
may not reboot until power is shutdown via
the iLO at that point.
If you must to manually cancel the pending SFW update, cancel the update via the iLO CLI command menu
using the ‘fw cancel’ command. Note: This should only be done under extenuating circumstances because it
might leave the system with incompatible iLO and SFW images. A full platform firmware update should be
immediately performed.
28