HP Smart Update Manager 6.3.0 Release Notes (Ed. 2)
HP SUM reports that component cp0205354.exe does not update if you Force or Rewrite it when
deploying to an HP ProLiant MicroServer
Suggested Action: No action. Deploy this component outside of HP SUM.
HP SUM does not deploy Brocade switch firmware updates greater than 7.2.0 if MAPS is enabled
Suggested Action: Disable MAPS before upgrading firmware to versions greater than 7.2.0.
CLI issues
The /use_web legacy CLI command does not work
Suggested Action: Use the GUI mode to download baselines from hp.com. Once HP SUM downloads
the baseline, you can use CLI mode to perform updates using the downloaded baseline.
HP SUM does not deploy multiple components in legacy CLI mode when listed separately in one
command
Suggested Action: Copy the components into a directory and use the /use_location command. If
you are deploying more than ten components, use this suggested action.
Report issues
HP SUM does not display VMware Smart Array firmware components on firmware reports
Suggested Action: No action. This is a known issue that will be resolved in a future version.
HP SUM generates XML report files in Console Mode if no report type is selected
Suggested Action: Choose the report type that you want to generate.
HP SUM generates blank XML reports in Console Mode if no parameters are selected
Suggested Action: No action necessary. This will be fixed in a future version.
HP SUM displays the session ID, not the node name, on the Activity screen when generating a report
Suggested Action: No action necessary. This will be fixed in a future version.
HP SUM does not include the correct number of components in a baseline from the HP website in an
Inventory report
Suggested Action: No action. This will be resolved in a future version.
Help issues
HP SUM does not support the node parameter for input files
Suggested Action: Do not use the node parameter for input files.
HP SUM does not display the online help on the Deploy screen when you select multiple nodes
Suggested Action: Do not open the help from the Deploy screen when you have multiple nodes selected.
HP SUM Console Help includes incorrect
Correct informationCommand
HP SUM console mode does not display more details when
you use the /getdetails parameter.
getnodes
HP SUM console mode does not support deploying updates
to groups.
deploy
22 Issues and suggested actions