HP Smart Update Manager 6.3.0 Release Notes (Ed. 2)

HP SUM unexpectedly stops running when you disconnect an ISO that contains a baseline that has
been added to HP SUM
Suggested Action: Do not disconnect from an ISO that contains a baseline that has been added to HP
SUM while HP SUM is running.
HP SUM adds an empty Additional Package to a baseline if the directory includes a .zip file
Suggested Action: Do one of the following:
Do not assign the empty Additional Package to nodes.
Move the .zip file to a directory mapped to a baseline.
HP SUM does not create a custom baseline if there is not enough free space, but HP SUM displays a
message that the baseline was created
Suggested Action: Make sure there is enough free space before creating a custom baseline.
Component issues
iPDU node components do not display the Force option
Suggested Action: HP SUM does not support downgrading or rewriting components for an iPDU node.
HP SUM 6.x does not configure Insight Management SNMP Agent components
Suggested Action: HP SUM applies the default configuration settings for the component. Review and
update the Insight Management SNMP Agents after HP SUM finishes installing the component.
HP SUM does not save configuration settings for SNMP components
Suggested Action: Configure SNMP settings outside of HP SUM and then copy the components to the
baseline.
HP SUM does not configure SMH component when using an input file
Suggested Action: No action. This will be resolved in a future version.
Component logs for iLO firmware displays incorrect details
Suggested Action: No action. This will be resolved in a future version.
HP SUM displays “Update returned an error” when deploying 32-bit Linux components to 64-bit Linux
nodes
Suggested Action: Install the 32-bit versions of the dependency libraries. For more information, see
“Prerequisites (page 4).
HP SUM displays an error on a ProLiant DL580 Gen8 server
Suggested Action: For information on this issue, see the Customer Advisory at http://
h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c04127124.
HP SUM on Windows 2012 systems displays two versions of some Windows 2012 components
Suggested Action: When running on Windows 2012, if HP SUM displays two versions of a component,
HP SUM is displaying the Windows 2012 and Windows 2012 R2 components. Click Available
Version and read the information to determine which version of the component to apply.
HP SUM displays “Update returned an error” when deploying the HP ProLiant Converged Network
Utility for Windows 2008 (component cp022111.exe)
Suggested Action: No action. This will be resolved in a future version of the component.
Issues and suggested actions 21