HP Smart Update Manager 6.3.0 Release Notes (Ed. 2)
HP SUM does not add all associated nodes when a firewall is enabled on Windows 2012 and
Windows 2012 R2 operating systems
Suggested Action: Make sure you shut down firewalls before adding additional nodes.
Baseline issues
HP SUM only includes firmware updates when you use the device option filter to create a custom
baseline
Description: HP SUM does not include software updates if you select the following options:
• Component Type: Both or Software.
• Device Type: Any device type you select from the list.
Suggested Action: No action necessary. This will be fixed in a future version.
HP SUM does not deploy Brocade switch firmware updates greater than 7.2.0 if MAPS is enabled
Suggested Action: Disable MAPS before upgrading firmware to versions greater than 7.2.0.
HP SUM unexpectedly quits running if it tries to pull a component from the web that does not exist
Suggested Action: No action. This will be resolved in a future version.
HP SUM reports incorrectly that a baseline was not deleted in Console mode
Suggested Action: No action necessary. This will be fixed in a future version. This occurs if the baseline
you are deleting is in the same directory as additional packages that are not in the baseline.
HP SUM does not assign the baseline for a node when added by IP range
Suggested Action: Edit the node after it has been added to assign the baseline. This will be resolved
in a future version.
HP SUM quits working when you delete a baseline
Suggested Action: Wait until HP SUM finishes performing inventory on a baseline before you delete
the baseline.
HP SUM does not display some RPM components in a baseline
Suggested Action: Update the component from another tool.
HP SUM does not correctly report the number of updates downloaded from the HP website
Suggested Action: No action. This will be resolved in a future version.
HP SUM does not present some RPMs for deployment even if they apply to the node
Suggested Action: Some RPMs do not contain the appropriate data for HP SUM to present them for
deployment. You can deploy these RPMS outside of HP SUM. The required data will be updated in a
future version of the RPM.
Advanced filters do not work as expected when you create a custom baseline
Suggested Action: No action. This will be resolved in a future version.
HP SUM does not build source RPMs
Suggested Action: Build the source RPM outside of HP SUM and then add the RPM to a baseline. After
HP SUM performs inventory on the baseline, it can deploy the RPM. This is how HP SUM designed to
work.
20 Issues and suggested actions