HP SUM reports incorrectly that a baseline was not deleted in Console mode
Suggested Action: No action necessary. This will be fixed in a future version. This occurs if the baseline
you are deleting is in the same directory as additional packages that are not in the baseline.
HP SUM does not assign the baseline for a node when added by IP range
Suggested Action: Edit the node after it has been added to assign the baseline. This will be resolved
in a future version.
HP SUM quits working when you delete a baseline
Suggested Action: Wait until HP SUM finishes performing inventory on a baseline before you delete
the baseline.
HP SUM does not display some RPM components in a baseline
Suggested Action: Update the component from another tool.
HP SUM cannot download updates from hp.com using a proxy script
Suggested Action: No action. This will be resolved in a future version.
HP SUM does not present some RPMs for deployment even if they apply to the node
Suggested Action: Some RPMs do not contain the appropriate data for HP SUM to present them for
deployment. You can deploy these RPMS outside of HP SUM. The required data will be updated in a
future version of the RPM.
HP SUM does not save custom ISOs if you do not select Make Bootable ISO file
Suggested Action: Save only bootable ISOs. This issue will be fixed in a future version.
HP SUM does not build source RPMs
Suggested Action: Build the source RPM outside of HP SUM and then add the RPM to a baseline. After
HP SUM performs inventory on the baseline, it can deploy the RPM. This is how HP SUM designed to
work.
HP SUM unexpectedly stops running when you disconnect an ISO that contains a baseline that has
been added to HP SUM
Suggested Action: Do not disconnect from an ISO that contains a baseline that has been added to HP
SUM while HP SUM is running.
HP SUM does not create a custom baseline if there is not enough free space, but HP SUM displays a
message that the baseline was created
Suggested Action: Make sure there is enough free space before creating a custom baseline.
Component issues
iPDU node components do not display the Force option
Suggested Action: HP SUM does not support downgrading or rewriting components for an iPDU node.
HP SUM running on Windows cannot configure Linux components
Suggested Action: Configure components outside of HP SUM, or run HP SUM on a Linux host.
HP SUM 6.x does not configure Insight Management SNMP Agent components
Suggested Action: HP SUM applies the default configuration settings for the component. Review and
update the Insight Management SNMP Agents after HP SUM finishes installing the component.