HP Smart Update Manager 6.2.0 Release Notes (Ed. 2)
HP SUM displays iLO4 nodes are ready for installation after update is applied
Suggested Action: No action. This will be resolved in a future version.
HP SUM displays the iLO firmware version as 0.0.0 for Linux nodes
Suggested Action: Make sure that the CHIF driver is installed so HP SUM can detect the correct iLO
firmware version. This applies to iLO2, iLO3, and iLO4.
HP SUM does not install iLO firmware updates when TPM is active
Suggested Action: Disable TPM if HP SUM does not apply iLO updates.
HP SUM displays a message that the firmware of Hard Disk Drives behind an HP Smart Array
H220/H222 controller is already updated when the firmware component is deployed online
Suggested Action: Updating these components when the Hard Disk Drives are behind an HP Smart
Array H220/H222 controller is only supported offline
HP SUM does not reboot a node after deploying updates in HP SUM offline interactive mode
Suggested Action: Reboot the server in the HP SPP offline environment.
HP SUM in GUI mode does not display the firmware or software you chose after pressing analyzing
groups
Suggested Action: Select all options for nodes individually, not as a group.
Aborting deployment and restarting deployment on iPDU nodes causes HP SUM to unexpectedly quit
Suggested Action: If you abort an iPDU update, shut down HP SUM and relaunch it before you attempt
to deploy the updates again.
HP SUM does not add all associated nodes when a firewall is enabled on Windows 2012 and
Windows 2012 R2 operating systems
Suggested Action: Make sure you shut down firewalls before adding additional nodes.
Baseline issues
HP SUM only includes firmware updates when you use the device option filter to create a custom
baseline
Description: HP SUM does not include software updates if you select the following options:
• Component Type: Both or Software.
• Device Type: Any device type you select from the list.
Suggested Action: No action necessary. This will be fixed in a future version.
HP SUM does not deploy Brocade switch firmware updates greater than 7.2.0 if MAPS is enabled
Suggested Action: Disable MAPS before upgrading firmware to versions greater than 7.2.0.
HP SUM does not display the component log files for Online HP 6Gb SAS BL Switch Firmware Smart
Component
Suggested Action: View the component log information in the file hpsum_detail_log.txt.
HP SUM unexpectedly quits running if it tries to pull a component from the web that does not exist
Suggested Action: No action. This will be resolved in a future version.
20 Issues and suggested actions