HP Smart Update Manager 6.2.0 Release Notes (Ed. 2)

Flash for Brocade Fibre Channel Host Bus Adapters - Windows Server 2012 R2 (x64), might incorrectly
appear as available for update
When updating Windows Server 2012 (non-R2) systems using HP SUM, the following components
might incorrectly appear as available for deployment and two driver components and two firmware
components might be shown in the HP SUM GUI as available for deployment on Windows 2012
target nodes. Those components are the HP Storage Brocade Storport Fibre Channel Host Bus Adapter
Driver for Microsoft Windows Server 2012 R2 and the HP Firmware Online Flash for Brocade Fibre
Channel Host Bus Adapters - Windows Server 2012 R2 (x64). For Microsoft Windows Server 2012
(non-R2) target nodes, select: Driver 3.2.1.0, cp019320 Firmware 2013.08.01, cp019374 Deselect:
Driver 3.2.3.1, cp021773 Firmware 2013.11.01, cp022023.
HP SUM session issues
HP SUM displays a certificate warning when connecting to HP SUM from a remote browser.
HP SUM versions 6.0.1, 6.2.0, and 6.3.0 contain a certificate that expires in 2016.
Suggested Action: You can ignore the warning, but HP recommends updating to HP SUM 6.3.1 or
later if you encounter this warning. HP SUM includes a newer certificate that does not display this
warning.
HP SUM does not start on ports lower than 1024 if you use the /port or /ssl_port parameters
Suggested Action: Use the following instructions to work around the issue:
1. Navigate to the hpsum.ini file in the temp directory, %temp%\HPSUM (Windows) or /tmp/
HPSUM (Linux).
NOTE: HP SUM creates this directory the first time you launch HP SUM. If you have not launched
HP SUM, launch it and then shut it down.
2. Open the file in a text editor, and edit the following items in the [HTTP] section.
port=63001 edit to port=80
ssl_port=63002 edit to ssl_port=443
3. Save the file.
4. Launch HP SUM. It now uses the 80 and 443 ports.
Running two sessions of HP SUM with the same node might cause problems
Suggested Action: Do not open multiple HP SUM sessions at the same time.
HP SUM 6.0.1 and later does not display nodes or baselines that an earlier version of HP SUM
accessed
Suggested Action: If you ran an earlier version of HP SUM 6.x and added nodes, run the HP SUM
6.0.1 hpsum_migration script to migrate the nodes from HP SUM 6.x. For more information, see
“Migrating nodes from 6.x to 6.3.0” (page 15).
HP SUM stops working if you log out of HP SUM while it is performing a task
Suggested Action: Wait for HP SUM to complete all tasks before logging out.
HP SUM generates large log files
Suggested Action: No action necessary. This is a known issue that will be resolved in a future version.
Manually remove the log file to if you want the drive space.
HP SUM might not display scroll bars or buttons correctly
Suggested Action: Set your screen resolution to 1024 x 768.
Issues and suggested actions 17