HP Smart Update Best Practices Planning Guide

http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?
docId=emr_na-c02838375.
CPLD firmware for ProLiant G7 and earlier servers require you to physically remove the
power source for 30 seconds before the update activates.
VC firmware update best practices
Check the compatibility matrix before you update an enclosure in mixed environments. For
more information, see “Updating mixed HP ProLiant and HP Integrity environments (page
21).
Run a health check before you update OA or VC firmware.
Verify that firewall programs are not blocking VC firmware updates.
Be sure that you update profiles if you move blades around and between enclosures.
NOTE: If you update a VC from 3.xx or higher, you might lose a VC domain configuration.
For more information, see the customer advisory website at http://h20564.www2.hp.com/
portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c03057267.
Review the latest VC release notes for any VC firmware release to determine any firmware
and driver changes needed for Ethernet, FC HBA, and CNA adapters in the servers.
NOTE: For more information about HP Virtual Connect release notes, see the HP Virtual
Connect website at http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/
?docId=emr_na-c02996704.
If you have problems with the VC Manager not communicating with the VC Ethernet module,
it might be a known issue. For more information, see the customer advisory website at http://
h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c02720395.
iLO for HP ProLiant servers firmware dependencies
iLO 3 firmware cannot be downgraded from version 1.25 to an earlier version without the
downgrade resetting some configuration data to the default value.
iLO 3 firmware 1.25 can cause a condition where the power is incorrectly reported and might
prevent some blades from powering on in a fully populated enclosure. Version 1.26 resolved
this issue.
Event ID 57 errors are corrected for iLO 2 by using firmware version 1.82 or later and HP
ProLiant iLO 2 Management Controller Driver for Windows 1.12.0.0 or later.
iLO 2 firmware 1.78 or later is required to update Power Management Controller firmware.
You cannot update iLO 2 firmware 2.00 through the iLO NIC Management interface.
Use iLO 2 firmware 1.81 or later to update CPLD firmware (HP ProLiant ML/DL300 series
servers).
c-Class enclosure best practices
Ensure that the FC HBA firmware included in a release set is supported by the external storage
vendor before you update the FC HBA.
8 Best practices tips and minimizing downtime