HP Serviceguard Storage Management Suite Version A.02.01.01 for HP-UX 11i v3 Release Notes, Edition 1 (May 2010)
The software on the HP-UX OE DVD is installed using update-ux. If a SG SMS OE bundle is
installed on your system and you attempt to install or upgrade to an HP-UX OE version that
includes Serviceguard and ECMT versions that are not supported with the SG SMS OE bundle,
update-ux will detect the incompatible software.
To avoid these potential installation conflicts, always upgrade the HP-UX OE and the SG SMS
OE bundle simultaneously as described in “Updating HP-UX Version and SG SMS Operating
Environment Bundle Simultaneously” (page 28).
If the HP-UX OE upgrade you want to install is not supported with the Serviceguard and ECMT
versions in the SG SMS bundle that is installed on your system, you must upgrade to an SG SMS
OE bundle that is supported with the HP-UX OE version you want to install.
See “Compatibility Information and Installation Requirements” (page 19) for more information
on bundle upgrades.
Known Problems
This section lists known problems in the HP Serviceguard Storage Management Suite version
A.02.01.01 for HP-UX 11i v3 at the time of publication. This list is subject to change without
notice. Details or more recent information may be available from your HP support representative
or the Hewlett-Packard IT Resource Center: http://www.itrc.hp.com (Americas and Asia Pacific)
or http://www.europe.itrc.hp.com (Europe).
To view details on these items: Login to ITRC.hp.com -> Search Knowledge base -> enter QXCR
number and search against "Engineering notes, solutions, bug reports, FAQs."
Table 1-8 Known Problems in the HP Serviceguard Storage Management Suite Version A.02.01.01
for HP-UX 11i v3
QXCR TITLEQXCR NUMBER
odm_gms_api_start_msgs fails during system startupQXCR1000555745
WARNING Messages Seen During SG SMS CFS Bundle UpgradeQXCR1000799055
Halting SG-CFS-vxfsckd failed; cluster crashedQXCR1000802805
VxVM commands are hanging in EDC testingQXCR1000819271
CVM node join timed out “Waiting for CVM to stabilize”QXCR1000829877
system panic: GAB detected network failure on long lived nodeQXCR1000832395
Synchronous Notification to client cmvxpingd timed outQXCR1000849095
Incorrect enclosure status during EDC testingQXCR1000856643
Documentation Errata
The following describes known problems with documentation included with HP Serviceguard
Storage Management Suite Version A.02.01.01 and workarounds for them. This is subject to
change without notice.
Known Problems 35