HP Serviceguard Storage Management Suite Version A.02.01.01 for HP-UX 11i v3 Release Notes, Edition 1 (May 2010)

c. Download the patches into a single file, extract the contents, and create a single depot
using the instructions included with the download.
d. Install the patches using the option patch_match_target=true”.
This ensures that only the patches from the depot that match the installed bundle are
installed.
5. If this is a new installation, and all required product patches have been installed, run
vxinstall.
If vxinstall has already been run on the systems, this step may be skipped.
This procedure completes initialization steps for:
— Veritas software prompting for Veritas licenses (use the default response - no)
— specification of a default disk group
— using enclosure-based naming
For information on vxinstall, see the Veritas 5.0 Installation Guide.
6. Verify a successful installation. Use the appropriate bundle product number in place of
T27xxCB, as follows: swverify T27xxCB
7. List components installed with: swlist -l product
8. If you have additional nodes in the cluster, repeat all steps for each node in the cluster. For
rolling upgrades, each node can rejoin the cluster after being upgraded. For offline upgrades
and new installations, start the cluster after all nodes have been installed or upgraded.
26 HP Serviceguard Storage Management Suite Version A.02.01.01 for HP-UX 11i v3 Release Notes