HP Serviceguard Storage Management Suite Version A.02.00 for HP-UX 11i v3 Release Notes, 3rd Edition, November 2008

NOTE: If HP-UX native multipathing is configured instead of Veritas DMP (Dymanic
Multipathing) with VxVM or CVM disk groups on HP-UX 11i v3, data corruption may occur.
Since DMP is enabled by default for all VxVM and CVM disk groups, no additional configuration
is required to enable DMP, and HP-UX native multipathing will be ignored by VxVM and CVM
disk groups. If patches PHCO_38235, PHKL_38236, PHKL_38241, and PHKL_38260 are installed,
HP-UX native multipathing is supported with VxVM only. However, VxVM disks configured
to use HP-UX native multipathing are not supported on systems with CVM installed.
What’s New with Serviceguard
HP Serviceguard Storage Management Suite version A.02.00 for HP-UX 11i v3 includes HP
Serviceguard version A.11.18. Patch PHSS_38424 for Serviceguard A.11.18 provides the following
new features and enhancements to SG SMS version 2.0 for HP-UX 11i v3 bundles:
HP Serviceguard Storage Management Suite Version A.02.00 bundles that include CFS can
now support CFS 5.0 nested mounts, up to a maximum of four levels of nesting. Patches
PHSS_38424 and PHSS_38400 enable this feature by default. To disable nested mounts, add
the following line to /etc/cmcluster.conf:
SGCFS_NESTED_MOUNT_SUPPORT=disabled
See “Guidelines for CFS Nested Mounts” (page 36) for more information.
Serviceguard now supports a maximum of eight CFS nodes per site, up to a maximum of
sixteen CFS nodes across two sites. See “Serviceguard Limitations with CFS” (page 36) for
more information.
Serviceguard now supports the increased number of LVM volume groups supported by the
HP-UX 11i v3 0809 Fusion release; the maximum number of volume groups you can configure
in a Serviceguard cluster is the maximum supported by HP-UX.
See the Serviceguard A.11.18 Release Notes available at: http://www.docs.hp.com/en/
ha.html#Serviceguard for more information.
Serviceguard now supports LVM 2.0 volume groups, both for data and the cluster lock.
See the Serviceguard A.11.18 Release Notes available at: http://www.docs.hp.com/en/
ha.html#Serviceguard for more information.
Mixed operating system clusters (HP–UX 11i v2 and 11i v3) are now supported with some
limitations.
See the Serviceguard A.11.18 Release Notes available at: http://www.docs.hp.com/en/
ha.html#Serviceguard for more information.
As of April 2008, new features and enhancements for HP Serviceguard version A.11.18 that are
supported in the SG SMS version 2.0 for HP-UX 11i v3 bundles include:
New, streamlined package-creation process using modular packages
Explicit support for external scripts
General-purpose support for package dependencies on the same node
General-purpose support for multi-node packages (volume groups must be mounted in
shared mode)
Support for online changes to AUTO_START_TIMEOUT cluster parameters
Increased support for VLAN
Support for HP Integrity Virtual Machines (HPVM) version 3.5
Support for cluster lock LUN
Support for PIDs up to maximum size supported by HP-UX
Support for hostnames up to 39 characters
Support for HP-UX device-management capabilities such as agile addressing
What’s New with the HP Serviceguard Storage Management Suite Version A.02.00 for HP-UX 11i v3 11