HP Serviceguard Storage Management Suite Version A.01.00 Release Notes, April 2008
HP Serviceguard Storage Management Suite Version A.01.00 Release Notes
Compatibility Information and Installation Requirements
Chapter 1 37
JAGaf80659 (SR8606420830) Missing disk group due to DGs not
auto-imported
• What is the problem? Sometimes disk shared disk groups fail to
import automatically when a cluster node starts.
• What is the workaround? Manually import the disk group with:
vxdg -s import <DISK_GROUP>
If this is a failover package, restart the package manually with:
cmrunpkg <PKG NAME>
If the disk group is created by cfsdgadm, then restart the diskgroup
with:
cfsdgadm activate <DISK_GROUP>
JAGaf80714 (SR8606420885) /sbin/gabconfig: open failed
• What is the problem? When SG-CFS-pkg starts, there is a very small
chance that the GAB driver cannot be configured, which causes the
node to TOC.
• What is the workaround? There is no workaround. The system will
reboot and SG-CFS-pkg startup should succeed.
JAGaf81684 (SR8606421859) Upgrade/downgrade installation
with LLT fails
• What is the problem? When installing bundles that include the LLT
module, after installing and removing a bundle that also included the
llt module the subsequent installation fails.
• What is the workaround? Use kcmodule llt=unused before trying
the subsequent installation. For example, the upgrade sequence from
T2775BA to T2776BA would be:
1. swremove -x autoreboot=true T2775BA
2. kcmodule llt=unused
3. swinstall -x autoreboot=true T2776BA