Managing Serviceguard 12th Edition, March 2006

Planning and Documenting an HA Cluster
Hardware Planning
Chapter 4142
lvdisplay -v
lvlnboot -v
vxdg list (VxVM and CVM)
vxprint (VxVM and CVM)
These are standard HP-UX commands. See their man pages for
information of specific usage. The commands should be issued from all
nodes after installing the hardware and rebooting the system. The
information will be useful when doing storage group and cluster
configuration. A printed listing of the output from the lssf command
can be marked up to indicate which physical volume group a disk should
be assigned to.
Hardware Configuration Worksheet
The following worksheet will help you organize and record your specific
cluster hardware configuration. This worksheet is an example; blank
worksheets are in Appendix F, “Blank Planning Worksheets,on
page 443. Make as many copies as you need. Complete the worksheet
and keep it for future reference.
SPU Information:
Host Name ____ftsys9___________ Series No ______rp8400____________
Memory Capacity ____128 MB _________ Number of I/O Slots ______12_______
=============================================================================
LAN Information:
Name of Name of Node IP Traffic
Subnet __Blue___ Interface ___lan0___ Addr___35.12.16.10__ Type ____HB___
Name of Name of Node IP Traffic
Subnet __Blue___ Interface ___lan2___ Addr_______________ Type _standby_
Name of Name of Node IP Traffic
Subnet __Red____ Interface ___lan1___ Addr___35.12.15.12_ Type _HB, client
=============================================================================
Network Failure Dections: ____INOUT___
=============================================================================
Serial (RS232) Heartbeat Interface Information: