HP Serviceguard Version A.11.17 Release Notes, March 2006 (revised)
Serviceguard Version A.11.17 Release Notes
Fixed in This Version
Chapter 144
JAGaf37969 (SR8606377706): IPv6 UDP network probe
messages should be retried
What was the problem? Serviceguard commands such as cmquerycl,
cmcheckconf and cmapplyconf fail with errors indicating non-uniform
connections detected between two IPv6 addresses similar to the
following:
Error: Non-uniform connection detected,
nodeA lanX fec0::1 successfully received from nodeB
lanY fec0::2
but nodeB lanY fec0::2 did not receive from nodeA
lanX fec0::1
This could be due to heavy network traffic, or heavy
load on nodeA
What was the resolution? Internally re-send the IPv6 UDP message(s) if
they were previously dropped.
JAGaf36081 (SR8606375787): Long boot times.
• What is the problem? Configurations using greater than 256 LUNs
with CVM on 11i v2 September 2004 update experience boot times of
greater than 1 hour.
September 2004 update experience boot times of greater than 1 hour.
• What was the resolution? Restrict configurations to 256 LUNs or less.
Please continue to check the status of this problem at
http://www2.itrc.hp.com for updated information. Search the
Technical Knowledge base for bug reports with the keyword
JAGaf36081.
JAGaf35978 (SR8606375675): hpux>
cmquercl|cmgetconf -c linux does not yield
CLUSTER_LOCK_LUN
What was the problem? If running cmviewcl or cmgetconf from an
HP-UX cluster against a cluster (with -C) running on linux with lock lun
configured, that information will be missing.
What was the resolution? Process lock lun information on an HP-UX
node.