ServiceGuard Manager Version A.01.00 Release Notes, December 2000
Chapter 1 15
ServiceGuard Manager Version A.01.00 Release Notes
Compatibility Information and Installation Requirements
— HA Admin Tools:
— Cluster Admin: opens SAM to the ServiceGuard cluster
administration section
— Cluster Config: opens SAM to the ServiceGuard cluster
configuration section
— Package Admin: opens SAM to the ServiceGuard package
administration section
— Package Config: opens SAM to the ServiceGuard package
configuration section
— Run Cluster: uses the cmruncl command to start a cluster
from the node you selected
— Halt Cluster: uses the sghaltcl command (a variant of the
cmhaltcl command) to halt the cluster of the node you selected
— Run Node: uses the cmrunnode command to join the selected
node to its cluster
— Halt Node: uses the cmhaltnode command to make the
selected node inactive in its cluster
— Net Diag Tools:
— View Interface Config: displays LAN interface configuration
parameters
— LAN Diag and Admin: launches the program lanadmin, which
adminsters and tests the local area network.
— Scan LAN interfaces: uses lanscan to display information
about each LAN device that has software support on the
system.
— IP Interface Stat: uses netstat to display statistics for
network interfaces and protocols, as well as the contents of
various network-related data structures. (Choose options to
filter output.)
— LVM tools:
— View Logical Volumes: displays the logical volumes currently
configured
— View Volume Groups: uses vgdisplay to show information