Understanding and Designing Serviceguard Disaster Recovery Architectures

Figure 26 Extended Distance Cluster with Two Data Centers and DWDM
Node A
Network Switch Network Switch
Node B
Cluster
Heartbeat
Network and
Storage
Connections
Data
replication
is being
done with
MirrorDisk/UX
Maximum
distance
100 kilometers
Node C Node D
Storage Storage
Cluster Lock
Site 1 Site 2
FC Switch
Cluster Lock
FC Switch
FC Switch
FC Switch
DWDMDWDM
DWDM DWDM
Network Switch Network Switch
In the figure 27, the alternate paths for both networking and Fibre Channel are configured through
separate redundant pairs of DWDM boxes. Each Fibre Channel switch has one ISL connected to
each DWDM box. You can also use a single DWDM box in each data center.The DWDM boxes
must be internally redundant and have no SPOFs, and have at least two dark fiber links between
them, each routed geographically differently, and the redundant standby fiber feature is configured
for the DWDM boxes. This cluster is not allowed to contain more than four nodes with Serviceguard.
For EC RAC clusters, the number of nodes allowed and the maximum distance supported vary,
depending upon the HP UX revision and the volume manager being used (see Table 2 (page 51),
Table 3 (page 51) and Table 4 (page 53) for details). Note that you cannot use SONET instead
of DWDM in this configuration, as SONET is not supported with dual cluster lock disks.
Extended Distance Cluster on HP-UX 65