Using Serviceguard Extension for RAC Version A.11.20 - (August 2011)

NOTE:
1. The “F” represents the Serviceguard failover time as given by the
max_reformation_duration field of cmviewcl v f line output.
2. SLVM timeout is documented in the whitepaper, LVM link and Node Failure Recovery Time.
Limitations of Cluster Communication Network Monitor
In Oracle Grid Infrastructure 11.2.0.2, using HAIP feature, Oracle allows to use a subnet for
Oracle Clusterware (CSS-HB) and RAC interconnect (RAC-IC) communication which is not configured
in SGeRAC cluster. So beginning with Oracle Grid Infrastructure 11.2.0.2 version,
CLUSTER_INTERCONNECT_SUBNET parameter must not be used in SGeRAC A.11.20 toolkit
Oracle Clusterware Multi-node and Oracle RAC database Multi-node packages.
CLUSTER_INTERCONNECT_SUBNET requires the subnet to be configured within the SGeRAC
cluster.
The Cluster Interconnect Monitoring feature does not coordinate with any feature handling subnet
failures (including self). The failure handling of multiple subnet failures may result in a loss of
services, for example:
A double switch failure resulting in the simultaneous failure of CSS-HB subnet and SG-HB
subnet on all nodes of a two-node cluster. (Assuming the CSS-HB subnet is different from SG-HB
subnet). Serviceguard may choose to retain one node while the failure handling of interconnect
subnets might choose to retain the other node to handle CSS-HB network failure. As a result,
both nodes will go down.
NOTE: To reduce the risk of failure of multiple subnets simultaneously, each subnet must
have its own networking infrastructure (including networking switches).
A double switch failure resulting in the simultaneous failure of CSS-HB subnet and RAC-IC
network on all nodes may result in loss of services (Assuming the CSS-HB subnet is different
from RAC-IC network). The failure handling of interconnect subnets might choose to retain one
node for CSS-HB subnet failures and to retain RAC instance on some other node for RAC-IC
subnet failures. Eventually, the database instance will not run on any node as the database
instance is dependent on clusterware to run on that node.
Cluster Interconnect Monitoring Restrictions
In addition to the above limitations, the Cluster Interconnect Monitoring feature has the following
restriction:
Cluster Lock device/Quorum Server/Lock Lun must be configured in the cluster.
Creating a Storage Infrastructure with LVM
In addition to configuring the cluster, you create the appropriate logical volume infrastructure to
provide access to data from different nodes. This is done with Logical Volume Manager (LVM) or
Veritas Cluster Volume Manager (CVM). LVM configuration is done before cluster configuration,
and CVM configuration is done after cluster configuration.
This section describes how to create LVM volume groups for use with Oracle data. Before configuring
the cluster, you create the appropriate logical volume infrastructure to provide access to data from
different nodes. This is done with Logical Volume Manager. Separate procedures are given for
the following:
Building Volume Groups for RAC on Mirrored Disks
Building Mirrored Logical Volumes for RAC with LVM Commands
40 Serviceguard Configuration for Oracle 10g, 11gR1, or 11gR2 RAC