Using Serviceguard Extension for RAC, 4th Edition, February 2007

Maintenance and Troubleshooting
Reviewing Cluster and Package States with the cmviewcl Command
Chapter 4 189
NODE STATUS STATE
ftsys10 up running
Network_Parameters:
INTERFACE STATUS PATH NAME
PRIMARY up 28.1 lan0
Serial_Heartbeat:
DEVICE_FILE_NAME STATUS CONNECTED_TO:
/dev/tty0p0 up ftsys9 /dev/tty0p0
The following shows status when the serial line is not working:
CLUSTER STATUS
example up
NODE STATUS STATE
ftsys9 up running
Network_Parameters:
INTERFACE STATUS PATH NAME
PRIMARY up 56/36.1 lan0
Serial_Heartbeat:
DEVICE_FILE_NAME STATUS CONNECTED_TO:
/dev/tty0p0 down ftsys10 /dev/tty0p0
NODE STATUS STATE
ftsys10 up running
Network_Parameters:
INTERFACE STATUS PATH NAME
PRIMARY up 28.1 lan0
Serial_Heartbeat:
DEVICE_FILE_NAME STATUS CONNECTED_TO:
/dev/tty0p0 down ftsys9 /dev/tty0p0
Viewing Data on Unowned Packages
The following example shows packages that are currently unowned, that
is, not running on any configured node. Information on monitored
resources is provided for each node on which package can run this
information allows you to identify the cause of a failure and decide where
to start the package up again.