Serviceguard Extension for RAC Version A.11.19 Release Notes, October 2009 (T1907-90051)

NOTE: Patches can be superseded or withdrawn at any time. Be sure to check the
status of any patch before downloading it.
Shared LVM Online Reconfiguration (SNOR) Patches
Table 1-1 list patches that are required to support the Shared LVM Online
Reconfiguration (SNOR) feature on HP-UX 11i v2.
Table 1-1 HP-UX 11i v2 Patches for SNOR
DescriptionPost DatePatch
s700_800 11.23 LVM Commands Patch20050927PHCO_33309
s700_800 11.23 LVM Cumulative Patch20050927PHKL_33312
Oracle Patches
Cluster Interconnect Subnet Monitoring
The Cluster Interconnect on Subnet Monitoring feature requires Oracle patch set 10.2.0.3.
NOTE: For specific Oracle patch installation requirements and procedures please
contact Oracle.
Defects and Fixes
The following defects have been fixed in SGeRAC version A.11.19. This list is subject
to change without notice. For the most current information contact your HP support
representative.
To view details on these items: Login to ITRC.hp.com —> Search Knowledge base —>
enter QXCR number and search against engineering notes, solutions, bug reports,
FAQs.
Table 1-2 SGeRAC A.11.19 Fixes
QXCR TitleQXCR Number
The configured nodes have to register cmgmsd
version when cluster starts. If any of the node does
not register, the failure message will be logged and
try again to register.
QXCR1000816558
The cmgmsd client gets an error and is killed when
it tries to retrieve data for a non-existing group.
QXCR1000741121
28 Serviceguard Extension for RAC Version A.11.19 Release Notes