Serviceguard Extension for RAC Version A.11.18 Release Notes, 5th Edition, October 2008

Table 1-1 HP-UX 11i v2 Patches for SNOR
DescriptionPost DatePatch
s700_800 11.23 LVM Commands Patch20050927PHCO_33309
s700_800 11.23 LVM Cumulative Patch20050927PHKL_33312
Oracle Patches
Cluster Interconnect Subnet Monitoring
The Cluster Interconnect on Subnet Monitoring feature requires Oracle patch set 10.2.0.3.
NOTE: For specific Oracle patch installation requirements and procedures please contact Oracle.
Fixes
The following defects have been fixed in SGeRAC version A.11.18. This list is subject to change
without notice. For the most current information contact your HP support representative.
Defect Number Problem and Resolution
CR: QXCR1000589887 (JAGag45439)
Problem: cmrunnode fails as the synchronized binary
configuration file on the up-rev node could not be
converted to the new format on the fly. Convert command
needs to be issued manually on the up-rev node before the
up-rev node can join the cluster.
Resolution: Fix is available in PHSS_37094 on 11i v2 and
PHSS_37095 on 11i v3.
Defect Number Problem and Resolution
SR: 8606443147 (JAGag00852) Problem: Improve error handling while validating clients
in cmgmsd. In certain rare cases, cmgmsd may not be able
to query the attributes of the sockets opened by its client
processes. In such cases, cmgmsd may hang and will
eventually be killed by cmcld.
Resolution: Fix is available in patch PHSS_34824.
Defect Number Problem and Resolution
SR: 8606462012 (JAGag17936) Problem: error register to group -- port does not belong to
pid. cmgmsd failed to call pstat_getsocket to retrieve
socket information due to less memory.
Resolution: Fix is available in patch PHSS_34824.
Defect Number Problem and Resolution
SR: 8606472718 (JAGag27561)
Problem: remove the well known ports. cmgmsd uses
internet socket and port number 5308 & 5408 for the
communication between cmgmsd and cmgmsd client. Do
not use ports 5308 and 5408 since they are already
registered by other companies.
Resolution: Fix is available in patch PHSS_34824.
Defect Number Problem and Resolution
SR:8606439160 (JAGaf97163)
Problem: crsctl stop crs caused many SIGKILL
messages in cmgmsd.log
Resolution: After sending the kill signal to the client,
cmgmsd waits for a short period of time before sending
20 Serviceguard Extension for RAC Version A.11.18 Release Notes