Continentalclusters Version A.08.00 Release Notes, April2011 (5900-1485)

1 and Site 2 of a Metrocluster and another two links are configured between each site
(Site 1 and Site 2) of Metrocluster to a far site, Site3. Using the third link ensures that
the data replication is restored to at least another site for any kind of data center wide
outages. The Delta Resync functionality allows quick restoration of the data replication
to the third site by copying only delta changes. This feature is supported for both 3DC
Sync/CAJ and 3DC CAJ/CAJ replications. This feature is supported on Serviceguard
versions A.11.19 and A.11.20. This feature does not require Serviceguard A.11.20
April 2011 patch PHSS_41628.
For more information on 3DC DR Solution using Tri-Link and Delta Resync functionality,
see Designing Disaster Recovery HA Clusters Using Metrocluster and Continentalclusters,
April 2011 (5900-1484) available at http://www.hp.com/go/hpux-serviceguard-docs
—> HP Metrocluster.
Support for Device Group Monitor in a 3DC DR Solution
With the introduction of the following patches, the Device Group Monitor (DGM) is
supported in a 3DC DR Solution:
Continentalclusters A.08.00 April 2011 patches (PHSS_41657 on 11i v2 and
PHSS_41658 on 11i v3)
Metrocluster with Continuous Access for P9000 and XP A.11.00 April 2011 patches
(PHSS_41663 on 11i v2 and PHSS_41664 on 11i v3)
Metrocluster Data Replication Enabler Toolkit A.10.00 April 2011 patches
(PHSS_41655 on 11i v2 and PHSS_41656 on 11i v3)
DGM provides the capability to monitor the status of all the device groups used in a
package configured in a 3DC environment, from the node where the package is running.
DGM provides the following functionalities:
Sends a notification message upon the change in a device group status.
Performs automatic resynchronization of the Continuous Access device group upon
link recovery.
In case of the 3DC DR Solution using Delta Resync configuration, it performs
automatic resynchronization of the Delta Resync pair upon some of the failures that
result in data not being replicated over the active Continuous Access Journal pair
to the third data center.
This feature is supported on Serviceguard versions A.11.19 and A.11.20. This feature
does not require Serviceguard A.11.20 April 2011 patch PHSS_41628.
For more information on Device Group Monitor in a 3DC DR Solution, see Designing
Disaster Recovery HA Clusters Using Metrocluster and Continentalclusters, April 2011
(5900-1484) available at http://www.hp.com/go/hpux-serviceguard-docs —> HP
Serviceguard Continentalclusters.
8 Continentalclusters Version A.08.00 Release Notes