Continentalclusters Version A.07.01 release notes, August 2010 (T2346-90015)
cpio files with the XP system) or the EMC Symmetrix SymCLI software or HP
StorageWorks Continuous Access EVA related software on all nodes.
3. If you are using the Oracle 8i Standby Database for logical data replication, purchase
the Enterprise Cluster Master toolkit product, and consult your HP representative
for more information about installing the template files.
Upgrading from Earlier Versions
If upgrading Continentalclusters from an earlier version, the following steps are
required:
1. Halt the ccmon package:
# cmhaltpkg ccmonpkg
2. Delete the old Continentalclusters configuration:
# cmdeleteconcl
3. Install to a new version of Continentalclusters.
4. If you have configured any monitoring definitions that have the notification type
TEXTLOG, ensure that the destination files are set under the
/var/opt/resmon/log/ directory.
5. Re-apply the Continentalclusters configuration using the original configuration
file.
# cmapplyconcl -C cmconl.config
For more information on editing configuration file and issuing configuration commands,
see Chapter 4 of the Designing Disaster Tolerant HA Clusters Using Metrocluster and
Continentalclusters document.
Compatibility Issues
Configuration with a metropolitan cluster as the primary cluster is supported in the
cascading failover configuration using Metrocluster with EMC SRDF and Continuous
Access XP. For information on configuration and setup, refer to the Cascading Failover
in a Continental Cluster white paper on http://www.hp.com/go/hpux-ha-monitoring-docs
-> HP Continentalcluster.
For details on using EMC SRDF, Continuous Access XP, or Continuous Access EVA,
refer to appropriate chapter of the Designing Disaster Tolerant High Availability Clusters
user’s guide.
12 Continentalclusters Version A.07.01 Release Notes