Continentalclusters Version A.06.00 Release Notes, December 2006 (T2346-90008)
Continentalclusters Version A.06.00 Release Notes
What’s In this Version
Chapter 1 9
more information on configuring single instance applications using CFS
or CVM, in Continentalclusters, refer to the Configuring Single Instance
Applications in CFS/CVM Environments in Continentalclusters
whitepaper, available at
www.docs.hp.com
This feature requires HP-UX 11i v2 and the selected HP Serviceguard
Storage Management Suite bundle which includes Serviceguard A.11.17,
CVM or CFS 4.1 support, and SGeRAC A.11.17 (if you need to configure
Oracle RAC).
IMPORTANT This feature is not supported in HP StorageWorks EVA disk array based
replication environment.
Other Changes
Following are the other changes in this release:
• If /etc/cmconcl/ccrac/ccrac.config file is configured, you must
specify the CCRAC_CLUSTER parameter for every recovery pair in
the ccrac.config file. If you do not specify this parameter, the recovery
process does not complete and the following error message is
displayed:
Cluster name is not specified as a set.
• When using TEXTLOG type notification, you must specify the
destination log file in the monitoring definition under
/var/opt/resmon/log.
If you specify any other location for logging, the following error
message appears:
The target after textlog ““ is not valid.
Please specify a file under /var/opt/resmon/log directory.
If you upgraded Continentalclusters but are still using the old
configuration file, the TEXTLOG location is still specified as
/var/adm/cmconcl. As a result, the following error message
appears:
The file path “s” specified for textlog is invalid.