User Service Guide, Fifth Edition - HP 9000 rp4410/4440
Figure 2-1 Airflow Through HP 9000 rp4410 and rp4440 Servers
Acoustic Noise Specification
The acoustic noise specification for the HP 9000 rp4410 or rp4440 server is 53 db LpA (sound
pressure level at bystander position in a dedicated computer room environment temperature of
<25°C).
Physical and Environmental Specifications
Table 2-7 provides temperature and airflow information for minimum, typical, and maximum
configurations for the HP 9000 rp4410 and rp4440 servers. It also lists the server and rack weights
and dimensions.
Table 2-7 Physical and Environmental Specifications
Overall Server
(W x D x H)
WeightCondition
Airflow, at
Maximum
Ambient degrees
C
1
Airflow, NominalTypical
Heat
Release
PedestalRackPedestalRackServer
Alone
180-264
VAC
W: 10.3 in
(26.1 cm)
D: 27.4 in
(69.5 cm)
H: 20.9 in
(53.0 cm)
W: 19 in
(48.2 cm)
D: 27.2 in
(69.0 cm)
H: 6.8 in
(17.3 cm)
115 lbs
(53 kg)
100 lbs
(45.4 kg)
88 lbs
(40 kg)
425
m3/hr
250
CFM
297
m3/hr
175 CFM
410 WattsMin.
Config.
1368 WattsMax.
Config.
1065 WattsTypical
Config.