Secure Path v2.0 for Sun Solaris Installation and Reference Guide
Secure Path (Fibre Channel) Installation 3-5
Compaq Confidential – Need to Know Required
Writer: Cyndi Vaccaro Project: StorageWorks Secure Path Version 2.0 for Sun Solaris Comments:
Part Number: AA-RKYDA-TE File Name: d-ch3 FC Installs.doc Last Saved On: 12/21/99 5:05 PM
a. If the controllers are in Transparent Failover Mode (see line 6 of
example controller output) then they must be reconfigured for
multiple-bus failover. Configure the RAID system controllers for
multiple-bus failover mode, using the commands below.
HSG80> set nofailover
HSG80 > set multibus_failover copy = this_controller
The controllers will restart in multiple-bus mode. After the other
controller has restarted, verify that both controllers are configured for
multiple-bus mode by issuing the following commands:
HSG80 > show this_controller
HSG80> show other_controller
Line 6 of the controller output should be similar to the following
(ignoring the value of the serial number):
Configured for MULTIBUS_FAILOVER with ZG90811309
b. Set the Preferred Path for each storage unit to specify the controller
that the unit will use upon the RAID system boot time as follows:
First, enter the following command to obtain a list of all units defined in
the RAID system:
HSG80 > show units full
An example of the “show units” output follows:
D11 DVGRPR0 (partition)
LUN ID: 6000-1FE1-0000-8920-0009-9030-5234-006E
NOIDENTIFIER
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAXIMUM_CACHED_TRANSFER_SIZE = 32
Access:
ALL
State:
ONLINE to this controller
Not reserved
NOPREFERRED_PATH
Size: 8533749 blocks
Geometry (C/H/S): ( 1680 / 20 / 254 )