HP StorageWorks Secure Path V3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide (AA-RU7VD-TE, February 2004)

Managing Secure Path
68 Secure Path v3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide
Example:
# spmgr display -av 2300-0
Server: swsp91 Report Created: Thu, Oct 02 15:58:32 2002
Command: spmgr display -av 2300-0
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
Adapter: 2300-0 Version: v.6.04.00
# spmgr display -c[v] [controller_serial_number]
The -c switch displays controller related information. If a parameter is supplied,
it must be a
controller_serial_number
. The command has four possible
forms:
Syntax:
# spmgr display -c
-cv
-c
controller_serial_number
-cv
controller_serial_number
Example:
# spmgr display –c
Server: sensodyne Report Created: Fri, Jul 12 10:58:44 2002
Command: spmgr display -c
Current Controller List
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
P56350A9IMN19M, P56350A9IMN0XI
Example:
# spmgr display -cv
Server: lotus Report Created: Tue, Oct 01 09:54:18 2002
Command: spmgr display -cv
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
Controller: P56350A9IMN19M Status: Operational
Vendor: HP
WWNN: 5008-05F3-0000-6FD0
WWPN1: 50001FE1500038A8
HBAs: 2300-1, 2300-2