HP StorageWorks Secure Path V3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide (AA-RU7VD-TE, February 2004)
Managing Secure Path
64 Secure Path v3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide
HSV110/HSV100
World Wide Node Name (WWNN): 5000-1FE1-0015-0AE0
World Wide LUN ID(WWLUNID):
6005-08B4-0001-40BF-0000-A000-1234-0000
Controller Serial Number: P4889B29LC01J
In the HSG80 and HSV110/HSV100 examples, the location of the sequence
1234 in the WWLUNID examples is unique to each LUN and is in a different
position in the array types.
For the HSV110, HSV100, and MSA1000, the controller serial number is a
14-position alphanumeric string and for the HSG80, controller serial numbers are
a 10-position alphanumeric string.
MSA1000:
World Wide Node Name (WWNN): 5008-05F3-0000-6FD0
World Wide LUN ID(WWLUNID):
6008-05F3-0000-6FD0-0000-0000-3F30-0043
Controller Serial Number: P56350A9IMN19M
The display command
This section describes the spmgr display commands and associated switch
parameters. Each switch results in a different type of display.
Note: The verbose flag may only be used with some, but not all, cases of the
command.
Syntax:
# spmgr display -a[v] [adapter]
-c[v] [controller_ser_num]
-d[v] [device]
-p path_instance
-r[v] [WWNN]
(no argument)