HP StorageWorks Secure Path V3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide (AA-RU7VD-TE, February 2004)

HSG80 Controller Failover Transitions
110 Secure Path v3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide
Changing from Multiple-bus Failover mode to no failover and
then to Transparent Failover mode
1. Check for connections on the storage system. For HSG80 controllers, enter
the following command:
CLI> show connections
2. Delete all connections by entering the following command for each
connection that is shown (if any):
CLI> delete
connection_name
Note: The connections will be regenerated later.
3. Check for units on the storage system:
CLI> show units
4. Delete all units by entering the following command for each unit (Dn) that is
shown (if any):
CLI> delete
dn
Note: The UNITs will be restored after the controller state is changed. HP recommends
that you record Dn values and associated information, as well as the storageset
information, for later use. The controller state change will not affect the data on the
storagesets.
5. If the controllers are currently in a failover mode, enter the following
command to shut down the OTHER_CONTROLLER:
CLI> set nofailover
6. Verify the current state of the controller, by entering the following command:
CLI> show this_controller