HSG80 Controller Failover Transitions
108 Secure Path v3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide
Changing from Transparent Failover to Multiple-bus Failover
mode
Regardless of whether you have defined UNITs for the RAID system, the
following steps implement Transparent Failover to Multiple-bus Failover.
1. Enter the following command at the CLI prompt:
CLI> set nofailover
This action causes the OTHER_CONTROLLER to shut down.
2. Enter the following command at the CLI prompt to verify the change to no
failover:
CLI> show this_controller
3. Restart the OTHER_CONTROLLER by pressing the RESET button on the
OTHER_CONTROLLER.
The OTHER_CONTROLLER will sound an alarm as it discovers the second
controller but detects that it is not bound in Failover mode. You can silence the
alarm and disregard the message about the controllers being misconfigured.
4. When the OTHER_CONTROLLER is online, enter the following command
to place the controllers into Multiple-bus Failover mode:
CLI> set multibus_failover copy=this_controller
This action copies all unit and connection information to the
OTHER_CONTROLLER and restarts both controllers.
Controller:
HSG80 ZG83502145 Software V85F-0, Hardware E03
NODE_ID = 5000-1FE1-0000-3350
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
-> Not Configured for dual-redundancy
Controller:
HSG80 ZG83502145 Software V85F-0, Hardware E03
NODE_ID = 5000-1FE1-0000-3350
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
-> Not Configured for dual-redundancy
-> Controller misconfigured -- other controller present