HP StorageWorks Secure Path V3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide (AA-RU7VD-TE, February 2004)

HSG80 Controller Failover Transitions
107Secure Path v3.0C for Linux and Linux Workgroup Edition Installation and Reference Guide
Changing from Transparent Failover to no failover mode
1. Enter the following command at the CLI prompt:
CLI> set nofailover
This action causes the OTHER_CONTROLLER to shut down.
2. Enter the following command to verify the change to no failover.
CLI> show this_controller
3. Restart the OTHER_CONTROLLER by pressing the RESET button on the
OTHER_CONTROLLER.
The OTHER_CONTROLLER sounds an alarm as it discovers the second
controller but detects that it is not bound in a failover mode. You can silence
the alarm and disregard the message about the controllers being
misconfigured.
Enter the following command to verify the change in controller state:
CLI> show this_controller
Note: This state change is important only if a controller is to be replaced, or if the state
is changing from Transparent Failover to Multiple-bus Failover or vice-versa. This is not
an ending state in itself.
Controller:
HSG80 ZG83502145 Software V85F-0, Hardware E03
NODE_ID = 5000-1FE1-0000-3350
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
-> Not Configured for dual-redundancy
Controller:
HSG80 ZG83502145 Software V85F-0, Hardware E03
NODE_ID = 5000-1FE1-0000-3350
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
-> Not Configured for dual-redundancy
-> Controller misconfigured -- other controller
present