HP StorageWorks Secure Path V2.0D Service Pack 2 for IBM AIX Release Notes (T3034-98201, May 2004)
Operating considerations
18 Secure Path v2.0D Service Pack 2 for IBM AIX Release Notes
Note: The following example uses a CLI Command.
HSG_CONTROL> SHOW UNITS
LUN Uses Used by
---------------------------------------------------------------
D1 DISK10000
D2 DISK20000
D4 DISK30000
D5 DISK30100
D6 DISK50300
D7 DISK30300
D8 DISK40100
D10 DISK40300
List the association of hdisks to RAID storage units using the Secure Path utility
/usr/cbxfc/cbxfcsm listall. In the following example, scsi2 and scsi3
are the HBAs for Secure Path. The first number (0) is the target designation and
the second number is the LUN.
# /usr/cbxfc/cbxfcsm listall
# Device Online Alternate
hdisk4 scsi3 0,0 scsi2 0,0
hdisk5 scsi3 0,1 scsi2 0,1
hdisk6 scsi3 0,2 scsi2 0,2
hdisk7 scsi3 0,4 scsi2 0,4
hdisk8 scsi3 0,5 scsi2 0,5
hdisk9 scsi3 0,7 scsi2 0,7
hdisk10 scsi3 0,8 scsi2 0,8
hdisk11 scsi3 0,10 scsi2 0,10
hdisk12 scsi3 0,6 scsi2 0,6
In the previous example, the hdisk4 assignment to LUN 0 is the Console LUN.
The Console LUN is always enabled and assigned LUN 0 when in SCSI-3 mode.
When operating in SCSI-2 mode, you may disable the console LUN. It is
recommended that LUN 0 be reserved for the command console LUN.