Release Notes HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8002, March 2009)
NOTE:
The device already exists in the boot option if the system displays Edit Existing Boot
Option or make a new entry [E-Edit N-New]:. Proceed but do not save the changes
to NVRAM; that is, proceed till step 10 and enter N when prompted.
9. Enter a description to display in the available boot options in the EFI boot manager; for example:
Enter New Description: 0/2/1/0.16.4.0.0.0.3
New BootOption Data. ASCII/Unicode strings only, with max of 240
characters
Enter BootOption Data Type [A-Ascii U-Unicode N-No BootOption] :
10. Enter N:
Enter BootOption Data Type [A-Ascii U-Unicode N-No BootOption] : None
11. Enter Y:
Save changes to NVRAM [Y-Yes N-No]:
12. Select Exit to return to the Boot option maintenance menu, as described in step 3. Select Change
Boot Order.
13. Select the newly added boot option and use the U key to move it to the desired position in the
boot order.
14. Select Save changes to NVRAM.
Identify the EFI path of the physical hardware path on systems that have Secure Path installed.
Determining the hardware path of active or standby path
To determine the hardware path of a standby path by using the spmgr display and ioscan
commands, see “Installing Secure Path on a SAN boot device” in the HP StorageWorks Secure Path
3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 installation and reference guide.
To determine the hardware path of a standby path:
1. Enter the spmgr display -dv boot device command on the host. In this example, the
boot device is /dev/dsk/c12t1d2.
spmgr display -dv c12t1d2
The following output is displayed:
Server:aphn1.india.hp.comReport Created: Fri, Jan 30 18:44:42 2004
Command: spmgr display -dvc12t1d2
Device:c12t1d2 Status:Operational[4 paths (1/0/2)] Storage: 5000-1FE1-
0015-0AE0 LUNID: 6005-08B4-0001-4920-0001-6000-04EA-0000 Preferred
Controller: None HBAs:td4td6
Item Device Controller HBA H/W_Path Instance
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
0 c12t1d2 P4889B49IM403L td4 255/255/0/2.3 c4t1d3 WWPN: N/A Path State:
Active
1 c12t1d2 P4889B49IM403L td6 255/255/0/2.3 c8t1d3 WWPN: N/A Path State:
Available
2 c12t1d2 P4889B49IM403A td4 255/255/0/2.3 c6t1d3 WWPN: N/A Path State:
Standby
12