Installation and Reference Guide HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8001, March 2009)

==================================================================
Deleted Arrays
==================================================================
Array ID Array Type
------------------------------------------------------------------
5000-1FE1-5000-B5D0 EVA-AA
------------------------------------------------------------------
==================================================================
Array Type : EVA-AA
Array ID : 5000-1FE1-0027-0CF0
------------------------------------------------------------------
Deleted Luns
------------------------------------------------------------------
6005-08B4-0010-0F17-0001-0000-0091-0000
==================================================================
Display LUN info using a device path
The autopath display <device path> command displays LUN info of the LUN using the device
path.
You can also use vdsf (in place of device path) in the autopath display command to display
the LUN info of the LUN.
Syntax:
autopath display <device path>
Example:
aphn5# autopath display /dev/dsk/c60t1d0
==================================================================
HPswsp Version : A.3.0F.04F.00F
==================================================================
Array WWN : 5005-08B3-0091-16A0
==================================================================
Lun WWN : 6005-08B3-0091-16A0-BFA5-F0A6-7FCE-0064
Virtual Device File : /hpap/dsk/hpap62
Load Balancing Policy : Shortest Service Time
Lun Timeout : Infinite Retry (-1)
==================================================================
Device Path Status
==================================================================
/dev/dsk/c59t1d0 Active
/dev/dsk/c60t1d0 Active
==================================================================
Secure Path for Active-Active disk arrays92