Installation and Reference Guide HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8001, March 2009)
Syslog messagesUser notification messagesEvent description
Multiple luns [ lun:
<WWLUNID> & lun: <WWLUNID>]
present at target/lun [tar-
get]/[lun] on array <array
WWN>. To obtain proper data
ensure the c#t#d# at the
specified target and lun is
not busy/mounted and Run
ioscan & insf -e respect-
ively.
1
Occurs when a device is un-
presented before deleting the
device with the spmgr delete
command, and you add new
device with the same virtual disk
or unit number as the old device,
as the new device is bound to the
WWLUNID of the old deleted
device. This leaves the newly ad-
ded LUN in an inconsistent state.
1
This message appears only if you have enabled the path polling.
Table 12 describes the way that Secure Path reports an event, such as a failure or state change to
the server through the Secure Path driver (hsx) or agent (spagent).
The Response action column shows where the event is logged.
• LOG is the /var/adm/syslog/syslog.log file.
• CONSOLE is the root console.
• NOTIFY is e-mail notification.
The Level column indicates the criticality of the event and is used by spmgr to allow the system
administrator to route events to specific users.
Table 12 Responses and severity level for supported events
LevelResponse actionEvent
WARNINGLOG+CONSOLE+NOTIFYPath failed
CRITICALLOG+CONSOLE+NOTIFYFailover condition detected
INFORMATIONALLOG+CONSOLE+NOTIFYFailover start
INFORMATIONALLOG+CONSOLE+NOTIFYFailover complete
INFORMATIONALLOG+CONSOLE+NOTIFYRestore start
INFORMATIONALLOG+CONSOLE+NOTIFYRestore complete
INFORMATIONALLOG+CONSOLE+NOTIFYRestore failed
WARNING - auto-restore is disabled until
next time quantum (1 hour)
LOG+CONSOLE+NOTIFYExcessive restores
CRITICALLOG+CONSOLE+NOTIFYAvailability changed
INFORMATIONALLOG+CONSOLE+NOTIFYSelect start
INFORMATIONALLOG+CONSOLE+NOTIFYSelect complete
WARNINGLOG+CONSOLE+NOTIFYSelect failed
INFORMATIONALLOGUnit attention
INFORMATIONALLOG+CONSOLESecure Path started
INFORMATIONALLOG+CONSOLE+NOTIFYConfiguration change
HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 77