Installation and Reference Guide HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8001, March 2009)

# spmgr display -c[v] controller_serial_number
The -c switch displays controller-related information. If a parameter is supplied, it must be a controller
serial number. The command has four possible forms:
Syntax:
# spmgr display -c
-cv
-c controller_serial_number
-cv controller_serial_number
Example:
# spmgr display –c
Server: hp.mydomain.com Report Created: Thu, Sep 13 16:30:23
2004
Command: spmgr display -c
Current Controller List
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
ZG10505167, ZG10506981
Example:
# spmgr display –cv
Server: hp.mydomain.com Report Created:Thu, Sep 13 16:30:23
2004
Command: spmgr display -cv
Controller: ZG10505167 Status: Operational
Vendor: HP
WWNN: 5000-1FE1-0010-5B00
HBAs: td0, td1
Controller: ZG10506981 Status: Operational
Vendor: HP
WWNN: 5000-1FE1-0010-5B00
HBAs: td0, td1
Example:
# spmgr display –c ZG10505167
Server:hp.mydomain.com Report Created: Thu, Sep 13 16:39:49 2004
Command: spmgr display -c ZG10505167
Controller: ZG10505167 Status: Operational
Vendor: HP
WWNN: 5000-1FE1-0010-5B00
HBAs: td0, td1
Example:
# spmgr display –cv ZG10505167
Server:hp.mydomain.com Report Created: Thu, Sep 13:16:41:17 2004
Command: spmgr display -cv ZG10505167
Controller: ZG10505167 Status: Operational
Vendor: HP
WWNN: 5000-1FE1-0010-5B00
HBAs: td0, td1
Item Device Controller HBA Parent Instance
= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
0 c16t0d0 ZG10505167 td0 0/0/255.0.0.0 c4t0d0
WWNN: 5000-1FE1-0010-5B00 Path State: Standby
1 c16t0d0 ZG10505167 td1 0/0/255.0.0.0 c10t0d0
WWNN: 5000-1FE1-0010-5B00 Path State: Standby
Secure Path for Active-Passive disk arrays44