Installation and Reference Guide HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8001, March 2009)

# fcmsutil /dev/td1 get remote all (to obtain all Target N_Port_ids in the
form 0x011200 for attached arrays)
# fcmsutil /dev/td1 replace_dsk Target N_Port_id#1
# fcmsutil /dev/td1 replace_dsk Target N_Port_id#2
# fcmsutil /dev/td1 replace_dsk Target N_Port_id#n
# fcmsutil /dev/tdn get remote all (to obtain all Target N_Port_ids in the
form 0x011200 for attached arrays)
# ioscan -fn
For example, if your server has HBAs td0 and td1, then you need to issue the following command
for both HBAs:
# fcmsutil /dev/td2 get remote all
Target N_Port_id is = 0x010000
Target state = DVS_READY
Symbolic Name = HSV210 - E8K_A5R1_0CE0_WIN_AA - CR0B42
Port Type = N_PORT
SLER Capable (supports Retry) = NO
Target Port World Wide Name = 0x50001fe100270ce8
Target Node World Wide Name = 0x50001fe100270ce0
Common Service parameters (all values shown in hex):
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Version_Hi: 9 Version_Low: 9
BB_Credit: 0 Ciro: 1
Alt_BBcred: 1 Rxsz: 800
Conseq: ff RO_Bitmap: 1
Resolution: 0 EDTOV(ms): 0
Vendor version (in hex) 0 0 0 0
-------------------------------------------------------------
Target N_Port_id is = 0x010100
Target state = DVS_READY
Symbolic Name = HSV210 - E8K_A5R1_0CE0_WIN_AA - CR0B42
Port Type = N_PORT
SLER Capable (supports Retry) = NO
Target Port World Wide Name = 0x50001fe100270ce9
Target Node World Wide Name = 0x50001fe100270ce0
Common Service parameters (all values shown in hex):
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Version_Hi: 9 Version_Low: 9
BB_Credit: 0 Ciro: 1
Alt_BBcred: 1 Rxsz: 800
Conseq: ff RO_Bitmap: 1
Resolution: 0 EDTOV(ms): 0
Vendor version (in hex) 0 0 0 0
-------------------------------------------------------------
From this sample output, use Target N_Port_ids 0x011000 and 0x011100 and run the following
commands:
HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 31