Installation and Reference Guide HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8001, March 2009)
DescriptionH/W typeS/W stateDriverH/W pathIClass
/dev/td1
FCP DomainINTERFACECLAIMEDfcp0/4/0/0.11fcp
FCP Device InterfaceINTERFACECLAIMEDfcpdev0/4/0/0.1.18.255.013ext_bus
DEVICECLAIMEDtgt0/4/0/0.1.18.255.0.09target
DEC HSG80DEVICECLAIMEDsdisk
0/4/0/0.1.18.255.0.
0.0
346disk
/dev/dsk/c13t0d0 /dev/rdsk/c13t0d0
FCP Device InterfaceINTERFACECLAIMEDfcpdev0/4/0/0.1.19.255.015ext_bus
DEVICECLAIMEDtgt0/4/0/0.1.19.255.0.010target
DEC HSG80DEVICECLAIMEDsdisk
0/4/0/0.1.19.255.0.
0.0
348disk
/dev/dsk/c15t0d0 /dev/rdsk/c15t0d0
3. Choose one of the following options:
• If you are using SCSI-3, proceed to Configuring SCSI-3 for HSG80-based systems to continue
the installation.
• If you are using SCSI-2, proceed to Installing Secure Path for Active-Passive disk arrays to
continue the installation.
Configuring SCSI-3 for HSG80-based systems
To configure your SCSI-3 for HSG80–based systems, follow the steps below:
1. Establish a terminal connection to the top controller’s CLI port to set the Operating System
mode for each Connection Name path as shown in the following example:
HSG80> show connections
Connection Unit
Name Operating System Controller Port Address Status Offset
!NEWCON1 WINNT OTHER 1 011500 OL other 0
HOST_ID=5006-0B00-0009-CE61ADAPTER_ID=5006-0B00-0009-CE60
!NEWCON2 WINNT THIS 1 021500 OL this 0
HOST_ID=5006-0B00-0009-CE61ADAPTER_ID=5006-0B00-0009-CE60
!NEWCON3 WINNT THIS 2 021500 OL this 0
HOST_ID=5006-0B00-0009-D8C7ADAPTER_ID=5006-0B00-0009-D8C6
!NEWCON4 WINNT OTHER 2 011500 OL other 0
HOST_ID=5006-0B00-0009-D8C7 ADAPTER_ID=5006-0B00-0009-D8C6
2. Change the operating system mode for each path shown to HP for SCSI-2 or HP_VSA for
SCSI-3. To do so, enter the following set of commands:
HSG80> set !NEWCON1 operating_system=HP (or HP_VSA)
HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 29