Installation and Reference Guide HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0 (5697-8001, March 2009)
• Configure SAN switches, as described in Configuring switches.
• Configure the StorageWorks RAID array, as described in Configuring the HSG80-based
StorageWorks array.
• Perform system configuration, as described in System configuration.
NOTE:
If the array has not been configured with your HP server, complete the procedure described in Installing
a new Secure Path configuration.
Installing a new Secure Path configuration
Perform the following steps before connecting the StorageWorks array to your host system:
1. Verify that HP-UX 11i v1.0 or 11i v2.0 is running.
2. See the HP StorageWorks Secure Path 3.0F Service Pack 4 for HP-UX 11i v1.0 and 11i v2.0
release notes to verify that your configuration is supported.
3. Use an FC utility to determine the world wide name (WWN) of the Fibre Channel (FC) adapters
within the server.
NOTE:
The appropriate FC utilities are fcmsutil and fcdutil.
An example of the fcmsutil command follows. Use the output of this command to record the WWN
of the HBAs that are connected to the array. This information is required to set up the host connection
to the HSV-based array and for verification of your configuration.
# fcmsutil /dev/td0
The instance number for the HBA is td0. The system displays the following:
Vendor ID is = 0x00103c
Device ID is = 0x001028
TL Chip Revision No is = 2.3
PCI Sub-system Vendor ID is = 0x00103c
I Sub-system ID is = 0x000006
Topology = PTTOPT_FABRIC
Local N_Port_id is = 0x011500
N_Port Node World Wide Name = 0x50060b000009ce61
N_Port Port World Wide Name = 0x50060b000009ce60
Driver state = ONLINE
Hardware Path is = 0/2/0/0
Number of Assisted IOs = 59812
Number of Active Login Sessions = 2
In this example, record the N_Port Port World Wide Name, 50060b000009ce60. Do this for
each HBA that is connected in the Secure Path configuration.
Complete the following steps to connect the array to your host system.
1. Connect FC cables between the FC HBAs and the ports on the HP SAN switch.
2. Connect FC cables from each Active-Passive array controller port to the HP SAN switch.
3. Complete the procedure described in Configuring switches.
Secure Path for Active-Passive disk arrays20